Heat Transfer in Fibrous Materials
Abstract
In fibrous material different types of heat transfer are present: conduction in solid phase constituting the insulation, radiation in the material, and heat transfer in the gas confined in the insulation. In this report the mechanisms of heat transfer are calculated theoretically. These calculations are verified experimentally by measurements on a glass fiber insulation in a specially constructed guarded hot plate apparatus. It is shown that the theories give a complete and consistent explanation of the influence of the mechanisms of heat transfer on the effective thermal conductivity of fibrous material.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A theoretical conductivity formula for fibrous material is proposed by Bankvall [5] based on the structure shown in Fig. 7.”
From Effective thermal conductivity of insulation materials for cryogenic LH2 storage tanks: A review (2023) · cites this paper as [5]
In the citing paper
“Similarly, Bankvall [5] derived an expression to estimate the radiation thermal conductivity in fibrous materials based on the average distance between fibers L and mean material thickness d :”
From Effective thermal conductivity of insulation materials for cryogenic LH2 storage tanks: A review (2023) · cites this paper as [5]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 24
- Schuhmeister, 1878, Versuche über das Wärmeleitungsvermogen der Baumwolle, Schafwolle und Seide, 283
- Baxter, 1946, The thermal conductivity of textiles, 105
- Verschoor, 1952, Heat transfer by gas conduction and radiation in fibrous insulations, Transactions of the American Society of Mechanical Engineers, 961, 10.1115/1.4015979 · DOI
- Stephenson, 1961, Thermal conductivity of porous materials, A.S.H.R.A.E. Journal, 75
- Hager, 1967, Radiant heat transfer in fibrous thermal insulation, Journal of Applied Physics, 3, 4663, 10.1063/1.1709200 · DOI
- Mumaw, J. R. , “Variations of the thermal conductivity coefficient for fibrous insulation materials,” M. S. Thesis, Ohio State University1968.
- Tye, 1969, Theory of thermal conductivity of fluids
- Pelanne, 1968, Experiments on the separation of heat transfer mechanisms in low-density fibrous insulation, 897
- Andersen, 1968, Mineralulds varmeisoleringsevne, Varme, 2, 6
- Strong, 1960, Flat panel vacuum thermal insulation, Journal of Applied Physics, 31, 39, 10.1063/1.1735416 · DOI
- Willye, 1954, An experimental investigation of the S. P. and resistivity phenomena in dirty sands, Journal of Petroleum Technology, 10.2118/302-G · DOI
- Krischer, 1956, Die Wärmeübertragung in feuchten, porigen Stoffen verschiedener Struktur, Forschung Auf Dem Gebiete Des Ingenieurwesens, 22, 1, 10.1007/BF02592657 · DOI
- Calvet, 1963, Transmission de la chaleur dans les matériaux poreaux a cellules ouvertes (granulaires ou fibreaux, Revue Génerale de Thermique, 24, 1383
- Lagarde, 1965, Considérations sur le transfert de chaleur en millieu poreus, Revue de l'Institute Francais du Pétrole, 20, 383
- Flynn, 1968, Thermal conductivity of Ceramics, 63
- Tye, 1969, Heat transmission in low conductivity materials
- 1970, Handbook of Chemistry and Physics
- Kannuluik, 1933, Conduction of heat in powders, 144
- Allcut, 1951, An analysis of heat transfer through thermal insulating materials, 232
- Kistler, 1935, The relation between heat conductivity and structure in silica aerogel, Journal of Physical Chemistry, 79, 10.1021/j150361a006 · DOI
- Larkin, 1959, Heat transfer by radiation through porous insulations, A. I. Ch. E. Journal, 5, 467, 10.1002/aic.690050413 · DOI
- Poltz, 1962, Einfluss der Wärmestrahlung aur die Isolierwirkung poräser Dämmschichten, Allgemeine Waremetechnik, 11, 64
- Koglin, 1967, Der Warmetransprt in Schaumstoffen
- Christiansen, The performance of glass fiber insulation under high vacuum, 10.1007/978-1-4757-0540-9_12 · DOI
Cited by
Sorted by citations
Effective thermal conductivity of insulation materials for cryogenic LH2 storage tanks: A review
Ratnakar, R. R., Sun, Z., & Balakotaiah, V. (2023) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2022.11.130 · Cited by 73
Metadata
- Authors
- Bankvall, C.
- Affiliations
- Lund University (SE)
- Corresponding author
- Bankvall, C
- Venue
- Journal of Testing and Evaluation
- Publisher
- ASTM International
- Published
- 1973-05-01
- Volume
- 1
- Issue
- 3
- Pages
- 235-243
- ISSN
- 0090-3973 (ISSN-L)
- OpenAlex
- W2206385639
- Cited by
- 156
- References
- 0
- Citations by year
- 2026: 1 · 2025: 8 · 2024: 4 · 2023: 3 · 2022: 4 · 2021: 2 · 2020: 2 · 2019: 6 · 2018: 6 · 2017: 2 · 2016: 3 · 2015: 5 · 2014: 3 · 2013: 5 · 2012: 5
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Testing and Evaluation (publishedVersion)
- Topics
- Physical Sciences › Engineering › Computational Mechanics › Heat and Mass Transfer in Porous Media
- Physical Sciences › Engineering › Computational Mechanics › Heat Transfer and Numerical Methods
- Physical Sciences › Materials Science › Polymers and Plastics › Textile materials and evaluations
- Keywords
- heat transfer, fibrous materials, thermal insulation, glass fiber insulation, effective thermal conductivity, radiation heat transfer, conduction, guarded hot plate apparatus, heat transfer mechanisms
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.