Detailed Description and Performance of a Passive Perfluorocarbon Tracer System for Building Ventilation and Air Exchange Measurements
The DOI matches its Crossref record.
Abstract
The manufacturing procedures for and the performance of a building air infiltration kit consisting of miniature passive perfluorocarbon tracer (PFT) permeation sources and passive adsorption tube samplers are described. With four PFT types available, homes and buildings with up to four separate zones can be evaluated fully under steady state conditions for the air infiltration and exfiltration rates from each zone as well as for the air exchange rates between zones using this inexpensive and nonobtrusive field kit. Complete details on deployment in homes and on gas chromatographic analysis of the passive samplers are presented. Examples of total air changes per hour (ACH) results in several studies showed average values between 0.25 to 0.64 h−1. A generalized correlation was used to characterize the leakiness of eleven homes in the United States and Canada, showing ACH dependency only on inside-outside temperature difference, on wind speed to the 1.5 power, and on a subjective terrain factor; the approach has application in evaluating weatherization performance. Details of multizone measurements in four homes provided insight into the role of attics, crawl spaces, and basements on the indoor air quality and weatherization needs for the living zone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tracer-gas techniques for measuring ventilation in a single zone
Sherman, M. H. (1990) · Building and Environment · doi:10.1016/0360-1323(90)90010-o · Cited by 291
Meng, Q. Y., Turpin, B. J., Korn, L., Weisel, C. P., Morandi, M., Colome, S., Zhang, J., Stock, T., Spektor, D., Winer, A., et al. (2005) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500378 · Cited by 266
Air pollution sources in offices and assembly halls, quantified by the olf unit
Fanger, P. O., Lauridsen, J., Bluyssen, P., & Clausen, G. (1988) · Energy and Buildings · doi:10.1016/0378-7788(88)90052-7 · Cited by 168
Field measurement of ventilation rates
Persily, A. K. (2016) · Indoor Air · doi:10.1111/ina.12193 · Cited by 164
Yamamoto, N., Shendell, D. G., Winer, A. M., & Zhang, J. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00622.x · Cited by 156
Ventilation in public housing: implications for indoor nitrogen dioxide concentrations
Zota, A., Adamkiewicz, G., Levy, J. I., & Spengler, J. D. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00375.x · Cited by 118
A review of air exchange rate models for air pollution exposure assessments
Breen, M. S., Schultz, B. D., Sohn, M. D., Long, T., Langstaff, J., Williams, R., Isaacs, K., Meng, Q. Y., Stallings, C., & Smith, L. (2014) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2013.30 · Cited by 69
“Based on a goodness of fit, evaluations of the hybrid model showed a mean absolute error of 13% in predicted AER across 11 homes.(40) For exposure assessors, the hybrid model could provide a screening-level or qualitative assessment of the AER.”
Method
Metadata
- Authors
- Dietz, R., Goodrich, R., Cote, E., & Wieser, R.
- Venue
- Measured Air Leakage of Buildings
- Published
- 1986-01-01
- Pages
- 203-264
- OpenAlex
- W1794547363
- Cited by
- 108
- References
- 0
- FWCI
- 4.75
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.