Cited by 67Neurological disorders and treatmentsMotor Control and AdaptationMuscle activation and electromyography studies

The Phase Difference Between Neural Drives to Antagonist Muscles in Essential Tremor Is Associated with the Relative Strength of Supraspinal and Afferent Input

Open access
Gallego, J. A., Dideriksen, J. L., Holobar, A., Ibanez, J., Glaser, V., Romero, J. P., Benito-Leon, J., Pons, J. L. +2 more·2015·Journal of Neuroscience

Abstract

The pathophysiology of essential tremor (ET), the most common movement disorder, is not fully understood. We investigated which factors determine the variability in the phase difference between neural drives to antagonist muscles, a long-standing observation yet unexplained. We used a computational model to simulate the effects of different levels of voluntary and tremulous synaptic input to antagonistic motoneuron pools on the tremor. We compared these simulations to data from 11 human ET patients. In both analyses, the neural drive to muscle was represented as the pooled spike trains of several motor units, which provides an accurate representation of the common synaptic input to motoneurons. The simulations showed that, for each voluntary input level, the phase difference between neural drives to antagonist muscles is determined by the relative strength of the supraspinal tremor input to the motoneuron pools. In addition, when the supraspinal tremor input to one muscle was weak or absent, Ia afferents provided significant common tremor input due to passive stretch. The simulations predicted that without a voluntary drive (rest tremor) the neural drives would be more likely in phase, while a concurrent voluntary input (postural tremor) would lead more frequently to an out-of-phase pattern. The experimental results matched these predictions, showing a significant change in phase difference between postural and rest tremor. They also indicated that the common tremor input is always shared by the antagonistic motoneuron pools, in agreement with the simulations. Our results highlight that the interplay between supraspinal input and spinal afferents is relevant for tremor generation.

Integrity signals

Registry

Crossref · 10.1523/jneurosci.0106-15.2015

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • High fluctuations in tremorous movements could be caused by subjective factors such as anxiety, distraction, or surprise.

    “This is a relevant issue to face during the experimental validation of these technologies because of the high fluctuations in tremorous movements (44, 87), which even could be caused by subjective factors such as anxiety, distraction, or surprise (44, 112, 115, 116).”

    From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [115]

  • The motor unit decomposition procedure was previously extensively validated on signals from various skeletal muscles.

    “We followed the decomposition procedure that was previously extensively validated on signals from various skeletal muscles (7,17,21,25–28).”

The citation lists haven’t been fetched yet

References 117 · Cited by 67

Authors
Gallego, J. A., Dideriksen, J. L., Holobar, A., Ibanez, J., Glaser, V., Romero, J. P., Benito-Leon, J., Pons, J. L., Rocon, E., & Farina, D.
Affiliations
  • Bernstein Center for Computational Neuroscience Göttingen (DE)
  • University of Maribor (SI)
  • Universidad Francisco de Vitoria (ES)
  • Consejo Superior de Investigaciones Científicas (ES)
Venue
Journal of Neuroscience
Published
2015-06-10
Volume
35
Issue
23
Pages
8925-8937
ISSN
  • 0270-6474 (ISSN-L)
  • 1529-2401
OpenAlex
W1893143467
Cited by
67
References
117
Citations by year
2026: 1 · 2025: 4 · 2024: 5 · 2023: 8 · 2022: 9 · 2021: 9 · 2020: 5 · 2019: 6 · 2018: 8 · 2017: 2 · 2016: 7 · 2015: 3
FWCI
4.70
Type
journal article
Language
en
Open access
Locations
  • Journal of Neuroscience (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • VBN Forskningsportal (Aalborg Universitet) (publishedVersion, other-oa)
  • Deposito Digital UFV (Francisco de Vitoria University) (submittedVersion, cc-by-nc-nd)
  • DIGITAL.CSIC (Spanish National Research Council (CSIC)) (submittedVersion)
  • GRO (submittedVersion)
  • Spiral (Imperial College London) (submittedVersion)
Funders
  • Northwestern University
  • European Commission (FP7-PEOPLE-2013, FP7-PEOPLE-2013-IOF, 627384)
  • FP7 People: Marie-Curie Actions (FP7-PEOPLE-2013, FP7-PEOPLE-2013-IOF)
Topics
  • Health Sciences › Medicine › Neurology › Neurological disorders and treatments
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
essential tremor, antagonist muscles, phase difference, Ia afferents, postural tremor, resting tremor, motoneuron pools, tremor generation, computational model
MeSH terms
Action Potentials, Aged, Animals, Computer Simulation, Electromyography, Female, Humans, Male, Models, Biological, Motor Neurons, Spinal Cord, Synapses, Vibrissae, Muscle, Skeletal, Statistics, Nonparametric, Essential Tremor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review