The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Nonlinear summation of M- and L-cone inputs to phasic retinal ganglion cells of the macaque
Open accessAbstract
We have studied the responses of ganglion cells in the macaque retina to stimuli that alternate in color. With most color combinations, the phasic retinal ganglion cells, which sum input from M- and L-cones in both center and surround, showed a response with twice the alternation frequency at equal luminance. This frequency doubling was directly related to the degree to which the M- and L-cones were stimulated out- of-phase with one another, and thus varied with the wavelength combinations used. It was absent with wavelength combinations that lay along tritanopic confusion lines, when at equal luminance the M- and L- cones are not modulated. Such a frequency-doubled response is evidence for a nonlinearity at or before M- and L-cone summation. The effect became much smaller or was abolished when the receptive field center alone was stimulated, indicating that its mechanism lies in the surround or in a center-surround interaction. Also, it was much more marked at high luminance levels, being almost absent at retinal illuminances below 100 td. Its origin is not clear, but it seems to derive more from the L- than the M-cone. The results imply that phasic cells, through this nonlinearity, could respond to the red-green equal luminance borders used in some psychophysical experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The contrast sensitivity of retinal ganglion cells of the cat
Enroth-Cugell, C., & Robson, J. G. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008107 · Cited by 2,625
Cited by
Recent models and findings in visual backward masking: A comparison, review, and update
Breitmeyer, B. G., & Ogmen, H. (2000) · Perception & Psychophysics · doi:10.3758/bf03212157 · Cited by 533
Luminance and chromatic modulation sensitivity of macaque ganglion cells and human observers
Lee, B. B., Pokorny, J., Martin, P. R., Valbergt, A., & Smith, V. C. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.002223 · Cited by 504
Self-citationInformation Processing in the Primate Retina: Circuitry and Coding
Field, G. D., & Chichilnisky, E. J. (2007) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.30.051606.094252 · Cited by 365
The color-opponent and broad-band channels of the primate visual system
Schiller, P. H., & Logothetis, N. K. (1990) · Trends in Neurosciences · doi:10.1016/0166-2236(90)90117-s · Cited by 311
Chapter 7 New views of primate retinal function
Kaplan, E., Lee, B. B., & Shapley, R. M. (1990) · Progress in Retinal Research · doi:10.1016/0278-4327(90)90009-7 · Cited by 282
Self-citation
Metadata
- Authors
- Lee, B., Martin, P., & Valberg, A.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 1989-04-01
- Volume
- 9
- Issue
- 4
- Pages
- 1433-1442
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W2141739023
- Cited by
- 175
- References
- 1
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nonlinear summation of M- and L-cone inputs to phasic retinal ganglion cells of the macaque. https://app.cochat.ai/papers/10.1523/jneurosci.09-04-01433.1989
- The paper
- Lee, B., Martin, P., & Valberg, A. (1989). Nonlinear summation of M- and L-cone inputs to phasic retinal ganglion cells of the macaque. The Journal of Neuroscience. https://doi.org/10.1523/jneurosci.09-04-01433.1989
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.