Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 96

The DOI matches its Crossref record.

Neural maps of interaural time and intensity differences in the optic tectum of the barn owl

Olsen, JF, Knudsen, EI, Esterly, SD · 1989 · The Journal of Neuroscience

Abstract

This report describes the binaural basis of the auditory space map in the optic tectum of the barn owl (Tyto alba). Single units were recorded extracellularly in ketamine-anesthetized birds. Unit tuning for interaural differences in timing and intensity of wideband noise was measured using digitally synthesized sound presented through earphones. Spatial receptive fields of the same units were measured with a free field sound source. Auditory units in the optic tectum are sharply tuned for both the azimuth and the elevation of a free field sound source. To determine the binaural cues that could be responsible for this spatial tuning, we measured in the ear canals the amplitude and phase spectra produced by a free field noise source and calculated from these measurements the interaural differences in time and intensity associated with each of 178 locations throughout the frontal hemisphere. For all frequencies, interaural time differences (ITDs) varied systematically and most strongly with source azimuth. The pattern of variation of interaural intensity differences (IIDs) depended on frequency. For low frequencies (below 4 kHz) IID varied primarily with source azimuth, whereas for high frequencies (above 5 kHz) IID varied primarily with source elevation. Tectal units were tuned for interaural differences in both time and intensity of dichotic stimuli. Changing either parameter away from the best value for the unit decreased the unit's response. The tuning of units to either parameter was sharp: the width of ITD tuning curves, measured at 50% of the maximum response with IID held constant (50% tuning width), ranged from 18 to 82 microsecs. The 50% tuning widths of IID tuning curves, measured with ITD held constant, ranged from 8 to 37 dB. For most units, tuning for ITD was largely independent of IID, and vice versa. A few units exhibited systematic shifts of the best ITD with changes in IID (or shifts of the best IID with changes in ITD); for these units, a change in the value of one parameter to favor one ear shifted the best value of the other parameter in favor of the same ear, i.e., in the direction opposite to that expected from “time-intensity trading.” Overall sound intensity had little or no effect on ITD tuning, but did increase the best IIDs of units tuned to nonzero IIDs. The tuning of units for ITD and IID changed systematically along different dimensions of the optic tectum to create coextensive, independent neurophysiological maps of ITD and IID.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1523/jneurosci.09-07-02591.1989

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 96

Metadata

Authors
Olsen, J., Knudsen, E., & Esterly, S.
Venue
The Journal of Neuroscience
Published
1989-07-01
Volume
9
Issue
7
Pages
2591-2605
ISSN
  • 0270-6474
  • 1529-2401
Cited by
96
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Neural maps of interaural time and intensity differences in the optic tectum of the barn owl. https://app.cochat.ai/papers/10.1523/jneurosci.09-07-02591.1989
The paper
Olsen, J., Knudsen, E., & Esterly, S. (1989). Neural maps of interaural time and intensity differences in the optic tectum of the barn owl. The Journal of Neuroscience. https://doi.org/10.1523/jneurosci.09-07-02591.1989

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.