X-ray computed tomography in Zernike phase contrast mode at 8 keV with 50-nm resolution using Cu rotating anode X-ray source
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
High-resolution X-ray computed tomography (XCT) enables nondestructive 3D imaging of complex structures, regardless of their state of crystallinity. This work describes a sub-50 nm resolution XCT system operating at 8 keV in absorption and Zernike phase contrast modes based on a commercially available Cu rotating anode laboratory X-ray source. The system utilizes a high efficiency reflective capillary condenser lens and high-resolution Fresnel zone plates with an outermost zone width of 35 nm and 700 nm structure height resulting in a spatial resolution better than 50 nm currently. Imaging a fragment of the solid oxide fuel cells (SOFC) with 50 nm resolution is presented as an application example of the XCT technique in materials science and nanotechnology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Three-dimensional reconstruction of a solid-oxide fuel-cell anode
Wilson, J. R., Kobsiriphat, W., Mendoza, R., Chen, H., Hiller, J. M., Miller, D. J., Thornton, K. S., Voorhees, P. W., Adler, S. B., & Barnett, S. A. (2006) · Nature Materials · doi:10.1038/nmat1668 · Cited by 906 · cited 2×
“The sample imaged with the XCT system was the tip of a piece broken off from a hollow tubular SOFC, with a solid YSZ electrolyte shell and a much thicker porous Ni-YSZ anode layer on the inside [8].”
MethodSoft X-ray microscopy at a spatial resolution better than 15 nm
Chao, W., Harteneck, B. D., Liddle, J. A., Anderson, E. H., & Attwood, D. T. (2005) · Nature · doi:10.1038/nature03719 · Cited by 851 · cited 2×
“The X-ray computed tomography (XCT) is a directimaging technique that has been successfully used over two decades for biological imaging in the high contrast “water window” (284–560 eV) X-ray energy range [6, 7].”
MethodImaging whole Escherichia coli bacteria by using single-particle x-ray diffraction
Miao, J., Hodgson, K. O., Ishikawa, T., Larabell, C. A., LeGros, M. A., & Nishino, Y. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.232691299 · Cited by 276 · cited 2×
“Currently there are two successful approaches to highresolution full field X-ray imaging: direct imaging which uses a high resolution Fresnel lens as the objective [1–3] and diffractive imaging that does not use a lens but requires coherent illumination currently only provided by synchrotron sources [4, 5].”
BackgroundMethodYin, G.-C., Tang, M., Song, Y., Chen, F., Liang, K. S., Duewer, F., Yun, W., Ko, C.-H., & Shieh, H. D. (2006) · Applied Physics Letters · doi:10.1063/1.2211300 · Cited by 101 · cited 1×
“In addition, a system that can be coupled with a synchrotron source operating at 7–18 keV has been introduced [2].”
BackgroundSelf-citation
Cited by
Maire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
Wildenschild, D., & Sheppard, A. P. (2013) · Advances in Water Resources · doi:10.1016/j.advwatres.2012.07.018 · Cited by 1,239
Priester, J. H., Ge, Y., Mielke, R. E., Horst, A. M., Moritz, S. C., Espinosa, K., Gelb, J., Walker, S. L., Nisbet, R. M., An, Y.-J., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1205431109 · Cited by 539
X-ray microtomography in biology
Mizutani, R., & Suzuki, Y. (2012) · Micron · doi:10.1016/j.micron.2011.10.002 · Cited by 217
Izzo, J. R., Joshi, A. S., Grew, K. N., Chiu, W. K. S., Tkachuk, A., Wang, S. H., & Yun, W. (2008) · Journal of The Electrochemical Society · doi:10.1149/1.2895067 · Cited by 216
Self-citationEpting, W. K., Gelb, J., & Litster, S. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201101525 · Cited by 188
A hard X-ray nanoprobe beamline for nanoscale microscopy
Winarski, R. P., Holt, M. V., Rose, V., Fuesz, P., Carbaugh, D., Benson, C., Shu, D., Kline, D., Stephenson, G. B., McNulty, I., et al. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512036783 · Cited by 188
“X-rays diffracted by the sample are collected by a zone plate which magnifies and focuses the image onto imaging optics and a CCD camera located at the end of the beamline (Tkachuk et al., 2007).”
BackgroundNanoscale Hard X-Ray Microscopy Methods for Materials Studies
Holt, M., Harder, R., Winarski, R., & Rose, V. (2013) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-071312-121654 · Cited by 183
Seyfferth, A. L., Webb, S. M., Andrews, J. C., & Fendorf, S. (2010) · Environmental Science & Technology · doi:10.1021/es101139z · Cited by 182
Guan, Y., Gong, Y., Li, W., Gelb, J., Zhang, L., Liu, G., Zhang, X., Song, X., Xia, C., Xiong, Y., et al. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2011.08.083 · Cited by 59
Human Connectome Mapping and Monitoring Using Neuronanorobots
Martins, N. R. B., Erlhagen, W., & Freitas, Jr. (2016) · Journal of Ethics and Emerging Technologies · doi:10.55613/jeet.v26i1.49 · Cited by 3
“The Xradia nanoXCT claims to be capable of providing a spatial resolution between 300-50 nm (Tkachuk et al. 2007).”
Background
Metadata
- Authors
- Tkachuk, A., Duewer, F., Cui, H., Feser, M., Wang, S., & Yun, W.
- Venue
- Zeitschrift für Kristallographie - Crystalline Materials
- Publisher
- Walter de Gruyter GmbH
- Published
- 2007-11-01
- Volume
- 222
- Issue
- 11
- Pages
- 650-655
- ISSN
- 2194-4946 (ISSN-L)
- 2196-7105
- OpenAlex
- W2078322918
- Cited by
- 207
- References
- 5
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.