Electrochemistry in Room Temperature Ionic Liquids: A Review and Some Possible Applications
Abstract
A review of electrochemistry in ionic liquids is presented, highlighting some particular examples, with the aim to compare any similarities and differences observed in RTILs to that observed in conventional solvents. The presence of impurities such as halide and water on the electrochemical window and viscosity of RTILs is discussed. Some fundamental electrochemical studies relating to mass transport, heterogeneous electron transfer kinetics and double-layer capacitance are compared to similar studies in conventional solvents, and the suitability of RTILs as solvents in electrochemical experiments is considered. The application of RTILs as replacements for conventional solvents in gas sensors is reviewed, focussing on the electrochemistry observed in RTILs for the following gases: oxygen, a mixture of oxygen and carbon dioxide, and ammonia. The low volatility and high thermal stability of RTILs renders them advantageous for the development of robust sensors under extreme conditions. Finally, the possibility for use of RTILs as solvents in electrosynthesis is discussed, focussing on two examples: the reactivity of electrogenerated bromine with cyclohexene, and the reduction of 4-nitrophenol. It is obvious that RTILs have the ability to offer many advantages over traditional solvents in the field of electrochemistry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ionic Liquids—New “Solutions” for Transition Metal Catalysis
Wasserscheid, P., & Keim, W. (2000) · Angewandte Chemie · doi:10.1002/1521-3773(20001103)39:21<3772::aid-anie3772>3.0.co;2-5 · Cited by 5,720
Influence of chloride, water, and organic solvents on the physical properties of ionic liquids
Seddon, K. R., Stark, A., & Torres, M.-J. (2000) · Pure and Applied Chemistry · doi:10.1351/pac200072122275 · Cited by 2,293
Air and water stable 1-ethyl-3-methylimidazolium based ionic liquids
Wilkes, J. S., & Zaworotko, M. J. (1992) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39920000965 · Cited by 1,883
Wilkes, J. S., Levisky, J. A., Wilson, R. A., & Hussey, C. L. (1982) · Inorganic Chemistry · doi:10.1021/ic00133a078 · Cited by 1,458
Non‐Haloaluminate Room‐Temperature Ionic Liquids in Electrochemistry—A Review
Buzzeo, M. C., Evans, R. G., & Compton, R. G. (2004) · ChemPhysChem · doi:10.1002/cphc.200301017 · Cited by 1,186
Self-citationH. Davis, J. (2004) · Chemistry Letters · doi:10.1246/cl.2004.1072 · Cited by 1,053
McEwen, A. B., Ngo, H. L., LeCompte, K., & Goldman, J. L. (1999) · Journal of The Electrochemical Society · doi:10.1149/1.1391827 · Cited by 845
Ionic Liquids: Solvents for the Electrodeposition of Metals and Semiconductors
Endres, F. (2002) · ChemPhysChem · doi:10.1002/1439-7641(20020215)3:2<144::aid-cphc144>3.0.co;2-# · Cited by 674
Chronoamperometric current at finite disk electrodes
Shoup, D., & Szabo, A. (1982) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(82)85171-1 · Cited by 628
Schröder, U., Wadhawan, J. D., Compton, R. G., Marken, F., Suarez, P. A. Z., Consorti, C. S., de Souza, R. F., & Dupont, J. (2000) · New Journal of Chemistry · doi:10.1039/b007172m · Cited by 554
Self-citation
Cited by
Understanding Ionic Liquids at the Molecular Level: Facts, Problems, and Controversies
Weingärtner, H. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200604951 · Cited by 1,543
Double Layer in Ionic Liquids: Overscreening versus Crowding
Bazant, M. Z., Storey, B. D., & Kornyshev, A. A. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.046102 · Cited by 1,098
Zhang, S., Zhang, J., Zhang, Y., & Deng, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00509 · Cited by 659
Development of OPLS-AA Force Field Parameters for 68 Unique Ionic Liquids
Sambasivarao, S. V., & Acevedo, O. (2009) · Journal of Chemical Theory and Computation · doi:10.1021/ct900009a · Cited by 613
A Review of Ionic Liquid Lubricants
Somers, A., Howlett, P., MacFarlane, D., & Forsyth, M. (2013) · Lubricants · doi:10.3390/lubricants1010003 · Cited by 605
Metadata
- Authors
- Silvester, D. S., & Compton, R. G.
- Venue
- Zeitschrift für Physikalische Chemie
- Publisher
- Walter de Gruyter GmbH
- Published
- 2006-10-01
- Volume
- 220
- Issue
- 10
- Pages
- 1247-1274
- ISSN
- 0044-3336 (ISSN-L)
- 2196-7156
- 0942-9352
- OpenAlex
- W2081243834
- Cited by
- 333
- References
- 33
- FWCI
- 12.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemistry in Room Temperature Ionic Liquids: A Review and Some Possible Applications. https://app.cochat.ai/papers/10.1524/zpch.2006.220.10.1247
- The paper
- Silvester, D. S., & Compton, R. G. (2006). Electrochemistry in Room Temperature Ionic Liquids: A Review and Some Possible Applications. Zeitschrift für Physikalische Chemie. https://doi.org/10.1524/zpch.2006.220.10.1247
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.