Consensus recommendations for the use of Ambulatory Glucose Profile in clinical practice
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Ambulatory Glucose Profile (AGP) is a way of displaying glucose data to reveal clinically relevant information. In a previously outlined study AGP was used to interpret glucose data recorded in patients with type 1 and 2 diabetes. These results, along with the published evidence and their own clinical experience, were discussed by an expert panel of diabetes specialists, with the aim of developing guidelines to assist clinicians in the analysis and interpretation of AGP. This group supports the consensus view that the AGP can be an effective standard for the analysis of glucose data. Interpretation guidelines are reported in the form of an algorithm, developed to demonstrate a step-by-step approach in undertaking the analysis of an AGP report in clinical practice. These are expected to improve glycaemic control, and might help patients to better understand their glucose levels and become more involved in the management of their diabetes. Where hypoglycaemia is identified, the recommendation is to focus, as a priority, on its management. At the end of the consultation, one key message should be reinforced with the patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bergenstal, R. M., Ahmann, A. J., Bailey, T., Beck, R. W., Bissen, J., Buckingham, B., Deeb, L., Dolin, R. H., Garg, S. K., Goland, R., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0051 · Cited by 307
Cited by
Outcome measures for artificial pancreas clinical trials: a consensus report
Maahs, D. M., Buckingham, B. A., Castle, J. R., Cinar, A., Damiano, E. R., Dassau, E., DeVries, J. H., Doyle, F. J., Griffen, S. C., Haidar, A., et al. (2016) · Diabetes Care · doi:10.2337/dc15-2716 · Cited by 211
Clinical Use of Continuous Glucose Monitoring in Adults with Type 2 Diabetes
Carlson, A. L., Mullen, D. M., & Bergenstal, R. M. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0024 · Cited by 177
Flash forward: a review of flash glucose monitoring
Leelarathna, L., & Wilmot, E. G. (2018) · Diabetic Medicine · doi:10.1111/dme.13584 · Cited by 167
Bergenstal, R. M. (2015) · Diabetes Care · doi:10.2337/dc15-0099 · Cited by 140
“the clinical measures of GV can actually have relevance to clinical decision making for the clinician and patient (18,20) (Fig.”
BackgroundClinical recommendations for the use of the ambulatory glucose profile in diabetes care
Kröger, J., Reichel, A., Siegmund, T., & Ziegler, R. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819883032 · Cited by 51
“Therefore, an essential component of any AGP evaluation is to assess the variability in glucose values.(2,5,6) Glucose fluctuations within a day (intraday) and from one day to another (interday) must both be taken into account here.”
Background
Metadata
- Authors
- Matthaei, S., DeAlaiz, R. A., Bosi, E., Evans, M., Geelhoed-Duijvestijn, N., & Joubert, M.
- Venue
- British Journal of Diabetes
- Publisher
- SAGE Publications
- Published
- 2014-11-24
- Volume
- 14
- Issue
- 4
- Pages
- 153
- ISSN
- 1474-6514 (ISSN-L)
- 1753-4305
- OpenAlex
- W2117958278
- Cited by
- 38
- References
- 1
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Consensus recommendations for the use of Ambulatory Glucose Profile in clinical practice. https://app.cochat.ai/papers/10.15277/bjdvd.2014.046
- The paper
- Matthaei, S., DeAlaiz, R. A., Bosi, E., Evans, M., Geelhoed-Duijvestijn, N., & Joubert, M. (2014). Consensus recommendations for the use of Ambulatory Glucose Profile in clinical practice. British Journal of Diabetes. https://doi.org/10.15277/bjdvd.2014.046
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.