Analysis of cut points for screening instruments for alcohol problems in the emergency room.
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of this study is to evaluate the performance of a number of alcohol screening instruments (CAGE, Brief MAST, AUDIT, TWEAK), in an emergency room population, against ICD-10 criteria for harmful drinking and for alcohol dependence from the CIDI, by gender, race and injury status. METHOD: A probability sample of patients were interviewed (N = 1,330) at the University of Mississippi Medical Center. Analyses were carried out on only current drinkers (n = 771; 58% of the sample). Instruments were compared on sensitivity, specificity and area under the curve using receiver operating characteristic (ROC) analysis to determine optimum cut points. RESULTS: Overall the TWEAK and AUDIT performed best (in relation to sensitivity and area under the ROC curve) at standard cut points (3 and 8, respectively) for both harmful drinking and alcohol dependence. These instruments did not perform equally well across all subgroups, however, particularly among women, and among whites where the CAGE, with a cut point of 1, outperformed both the TWEAK and AUDIT at standard cut points. The TWEAK at a cut point of 2 also did as well as the CAGE at a cut point of 1 among women. CONCLUSION: These data suggest that standard screening instruments do not perform equally well across ethnic and gender subgroups and that consideration of alternative cut points may be appropriate in some populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SAUNDERS, J. B., AASLAND, O. G., BABOR, T. F., DE LA FUENTE, J. R., & GRANT, M. (1993) · Addiction · doi:10.1111/j.1360-0443.1993.tb02093.x · Cited by 13,597
Cited by
The alcohol use disorders identification test: an update of research findings
Reinert, D. F., & Allen, J. P. (2007) · Alcoholism: Clinical and Experimental Research · doi:10.1111/j.1530-0277.2006.00295.x · Cited by 1,397
“Although the AUDIT’s performance has been weaker among blacks in some studies (Cherpitel, 1998; Cherpitel and Bazargan, 2003; Cherpitel and Clark, 1995), in others the AUDIT performed equally well among blacks and whites (see Cherpitel, 1997) or even as slightly more accurate among blacks in identifying harmful use (C…”
MethodResultThe Alcohol Use Disorders Identification Test (AUDIT): A review of recent research
Reinert, D. F., & Allen, J. P. (2002) · Alcoholism: Clinical and Experimental Research · doi:10.1111/j.1530-0277.2002.tb02534.x · Cited by 1,143
A Review of Research on the Alcohol Use Disorders Identification Test (AUDIT)
Allen, J. P., Litten, R. Z., Fertig, J. B., & Babor, T. (1997) · Alcoholism: Clinical & Experimental Research · doi:10.1097/00000374-199706000-00008 · Cited by 957
Alcohol Screening Questionnaires in Women: A Critical Review
Bradley, K. A., Boyd-Wickizer, J., Powell, S. H., & Burman, M. L. (1998) · JAMA · doi:10.1001/jama.280.2.166 · Cited by 403
Longabaugh, R., Woolard, R. E., Nirenberg, T. D., Minugh, A. P., Becker, B., Clifford, P. R., Carty, K., Licsw, Sparadeo, F., & Gogineni, A. (2001) · Journal of Studies on Alcohol · doi:10.15288/jsa.2001.62.806 · Cited by 359
Metadata
- Authors
- Cherpitel, C. J.
- Venue
- Journal of Studies on Alcohol
- Publisher
- Alcohol Research Documentation, Inc.
- Published
- 1995-11
- Volume
- 56
- Issue
- 6
- Pages
- 695-700
- ISSN
- 0096-882X (ISSN-L)
- 1934-2683
- OpenAlex
- W2136879440
- Cited by
- 152
- References
- 1
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.