CoChat

Mass spectrometry and immunoassay: how to measure steroid hormones today and tomorrow

Taylor, Angela E, Keevil, Brian, Huhtaniemi, Ilpo T · 2015 · European Journal of Endocrinology

The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.

Abstract

Summary: The recent onslaught of mass spectrometry (MS) to measurements of steroid hormones, including demands that they should be the only acceptable method, has confused clinicians and scientists who have relied for more than 40 years on a variety of immunoassay (IA) methods in steroid hormone measurements. There is little doubt that MS methods with their superior specificity will be the future method of choice in many clinical and research applications of steroid hormone measurement. However, the majority of steroid measurements are currently, and will continue to be, carried out using various types of IAs for several reasons, including their technical ease, cost and availability of commercial reagents. Speedy replacement of all IAs with MS is an unrealistic and unnecessary goal, because the availability of MS measurements is limited by cost, need of expensive equipment, technical demands and lack of commercial applications. Furthermore, IAs have multiple well-known advantages that vindicate their continuing use. The purpose of this article is to elucidate the advantages and limitations of the MS and IA techniques from two angles, i.e. promotion of MS and defence of IA. The purpose of the text is to give the reader an unbiased view about the current state and future trends of steroid analysis and to help him/her choose the correct assay method to serve his/her diagnostic and research needs.

Overview

Integrity signals

Registry

Crossref · 10.1530/eje-15-0338

Cites

74 of 74 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 74 references

Cited by

See all 320

Metadata

Authors
Taylor, A. E., Keevil, B., & Huhtaniemi, I. T.
Affiliations
University of Turku (FI)
Corresponding author
  • Keevil, Brian
  • Huhtaniemi, Ilpo T
Venue
European Journal of Endocrinology
Published
2015-08
Volume
173
Issue
2
Pages
D1-D12
ISSN
  • 0804-4643 (ISSN-L)
  • 1479-683X
OpenAlex
W2110473840
Cited by
320
References
74
Citations by year
2026: 20 · 2025: 23 · 2024: 31 · 2023: 42 · 2022: 35 · 2021: 33 · 2020: 27 · 2019: 33 · 2018: 32 · 2017: 26 · 2016: 15 · 2015: 3
FWCI
2.45
Type
journal article
Language
en
Open access
closed
Locations
  • European Journal of Endocrinology (publishedVersion)
  • PubMed (publishedVersion)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
Keywords
steroid hormones, mass spectrometry, immunoassay, steroid hormone measurement, method comparison
MeSH terms
Animals, Chromatography, Liquid, Hormones, Humans, Immunoassay, Mass Spectrometry, Steroids, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mass spectrometry and immunoassay: how to measure steroid hormones today and tomorrow. https://app.cochat.ai/papers/10.1530/eje-15-0338
The paper
Taylor, A. E., Keevil, B., & Huhtaniemi, I. T. (2015). Mass spectrometry and immunoassay: how to measure steroid hormones today and tomorrow. European Journal of Endocrinology. https://doi.org/10.1530/eje-15-0338

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.