Performance Evaluation of the ADVIA 2120 Hematology Analyzer: An International Multicenter Clinical Trial
Open accessThe DOI matches its Crossref record.
Abstract
Automated cell counters are widely used in modern clinical laboratories to provide reliable, fast, and cost-effective complete blood counts (CBCs), white blood cell differentials, and reticulocyte measurements. In addition, some advanced instruments provide novel parameters, such as the hemoglobin content of reticulocytes or the percentage of hypochromic cells, and are capable of analysis of a variety of body fluids. Bayer recently introduced the ADVIA 2120 system as an automation-ready cell counter for mid- to high-volume testing in the clinical laboratory. This instrument, which builds on the established technology of the ADVIA 120 system, operates with a cyanide-free method for hemoglobin measurement, has a new user interface, and can routinely analyze biological fluid samples in addition to blood. We used 749 samples from 6 worldwide trial sites to evaluate the clinical performance of this new device. Accuracy of the ADVIA 2120 system versus its predecessor model, the ADVIA 120 system, was excellent for all CBC and white cell differential parameters and reticulocyte counts (all correlation coefficients except for basophils >0.9). Correlation of the white cell differential with the standard manual method and within-run precision of the ADVIA 2120 system also was very good. Use of the novel cyanide-free method for hemoglobin measurement had no clinically significant impact on hemoglobin results, even in patients with hemoglobinopathies. We concluded that the ADVIA 2120 system has clinically equivalent performance to the ADVIA 120 system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Preoperative neutrophil-lymphocyte ratio and outcome from coronary artery bypass grafting
Gibson, P. H., Croal, B. L., Cuthbertson, B. H., Small, G. R., Ifezulike, A. I., Gibson, G., Jeffrey, R. R., Buchan, K. G., El-Shafei, H., & Hillis, G. S. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.06.043 · Cited by 382
Influence of a light meal on routine haematological tests.
(2010) · PubMed Central · doi:10.2450/2009.0142-09 · Cited by 71
Gavala, A., & Myrianthefs, P. (2017) · Heart & Lung · doi:10.1016/j.hrtlng.2017.04.003 · Cited by 38
Evaluation of different mixing procedures for K2 EDTA primary samples on hematological testing
Lippi, G., Salvagno, G. L., Montagnana, M., Banfi, G., & Guidi, G. C. (2007) · Laboratory Medicine · doi:10.1309/95r8a56bdn10auuh · Cited by 24
Metadata
- Authors
- HARRIS, N., JOU, J. M., DEVOTO, G., LOTZ, J., PAPPAS, J., WRANOVICS, D., WILKINSON, M., FLETCHER, S. R., & KRATZ, A.
- Venue
- Laboratory Hematology
- Publisher
- Carden Jennings Publishing Co.
- Published
- 2005-03-01
- Volume
- 11
- Issue
- 1
- Pages
- 62-70
- ISSN
- 1080-2924 (ISSN-L)
- OpenAlex
- W2024126700
- Cited by
- 105
- References
- 0
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.