The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The International Consensus Group for Hematology Review: Suggested Criteria for Action Following Automated CBC and WBC Differential Analysis
Open accessAbstract
In the half century since the first use of automated analyzers, manual techniques, especially microscopic examination of a stained blood film, have complemented analyzer results to provide a comprehensive hematology report on a patient's blood sample. Over the years, as the capabilities and performance of automated analyzers have improved, the respective roles of the automated analyzer and the complementary procedures have changed. Manual action (most commonly smear review) following automated analyzer results is usually triggered by determining whether the results trigger one of a series of criteria for review of results. There is little uniformity among different laboratories on criteria for action. Recognizing the long-standing need for generally accepted guidelines ("rules") which could be applied to criteria for review of CBC and differential results from automated hematology analyzers, Dr. Berend Houwen invited 20 experts to a meeting in the Spring of 2002 to discuss the issues and determine the most appropriate criteria. At this meeting, 83 rules were developed by consensus agreement. These rules were then tested in 15 laboratories on a total of 13,298 blood samples. After a detailed analysis of the data, the rules were refined and consolidated to produce 41 rules that are presented here. They include rules for first-time samples as well as delta rules for repeat samples within 72 hours from a patient. It is hoped that these rules will be useful to a large number of hematology laboratories worldwide. To facilitate validating these rules in individual laboratories before implementation in routine operation for patient samples, a suggested protocol is attached to this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beiträge zur Kenntniss der Anilinfärbungen und ihrer Verwendung in der mikroskopischen Technik
Ehrlich, P. (1877) · Archiv für Mikroskopische Anatomie · doi:10.1007/bf02933937 · Cited by 334
Cited by
Automated Blood Cell Counts: State of the Art
Buttarello, M., & Plebani, M. (2008) · American Journal of Clinical Pathology · doi:10.1309/ek3c7ctdknvpxvtn · Cited by 355
Very Deep Convolutional Neural Networks for Morphologic Classification of Erythrocytes
Durant, T. J. S., Olson, E. M., Schulz, W. L., & Torres, R. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2017.276345 · Cited by 49
Metadata
- Authors
- BARNES, P. W., MCFADDEN, S. L., MACHIN, S. J., & SIMSON, E.
- Venue
- Laboratory Hematology
- Publisher
- Carden Jennings Publishing Co.
- Published
- 2005-06-01
- Volume
- 11
- Issue
- 2
- Pages
- 83-90
- ISSN
- 1080-2924 (ISSN-L)
- OpenAlex
- W2025031772
- Cited by
- 294
- References
- 1
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The International Consensus Group for Hematology Review: Suggested Criteria for Action Following Automated CBC and WBC Differential Analysis. https://app.cochat.ai/papers/10.1532/lh96.05019
- The paper
- BARNES, P. W., MCFADDEN, S. L., MACHIN, S. J., & SIMSON, E. (2005). The International Consensus Group for Hematology Review: Suggested Criteria for Action Following Automated CBC and WBC Differential Analysis. Laboratory Hematology. https://doi.org/10.1532/lh96.05019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.