Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 183

The DOI matches its Crossref record.

Comparative Toxicity of Standard Nickel and Ultrafine Nickel in Lung after Intratracheal Instillation

Open access
Zhang, Qunwei, Kusaka, Yukinori, Zhu, Xinqiang, Sato, Kazuhiro, Mo, Yiqun, Kluz, Thomas, Donaldson, Kenneth · 2003 · Journal of Occupational Health

Abstract

Comparative Toxicity of Standard Nickel and Ultrafine Nickel in Lung after Intratracheal Instillation: Qunwei Zhang, et al.; Department of Environmental Health, School of Medicine, Fukui Medical University—A comparison was made of the bronchoalveolar lavage fluid (BALF) response to ultrafine nickel (Uf‐Ni) and standard‐sized nickel (Std‐Ni). Rats were intratracheally instilled with 0, 0.1, 0.5, 1 and 5 mg Uf‐Ni and Std‐Ni, respectively. At 3 d after instillation, the body weight and wet lung weight were determined. At the same time, BALF was analyzed for lactate dehydrogenase (LDH), total protein (TP), tumor necrosis factor‐alpha (TNF‐alpha), and total cell and differential cell counts. The results showed that indicators of lung injury and inflammation in BALF were markedly raised with increased Uf‐Ni and Std‐Ni for each from 0 to 1 mg, and there were no differences in the indices between instillation of Uf‐Ni at 1 mg and 5 mg. The results also showed that the effects of Uf‐Ni on the indices were significantly higher than those of Std‐Ni. Additional groups of rats were intratracheally instilled with 1 mg of Uf‐Ni or Std‐Ni, and wet lung weight and BALF profiles were analyzed at 1, 3, 7, 15 and 30 d later. The effect of Uf‐Ni and Std‐Ni on indices that can be presumed to reflect epithelial injury and permeability (LDH or TP), and release of proinflammatory cytokine (TNF‐alpha) were increased throughout the 30 d post‐exposure and the effects of Uf‐Ni on these indices were significantly higher than those of Std‐Ni from 1 to 30 d after instillation. Moreover, the number of neutrophils and LDH activity in BALF of rats after exposure to Uf‐Ni were significantly greater than those of Std‐Ni‐exposed rats up to 30 d after instillation. Our findings suggest that Uf‐Ni has a much more toxic effect on the lung than St‐Ni, but the mechanism remains to be elucidated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1539/joh.45.23

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 183

Metadata

Authors
Zhang, Q., Kusaka, Y., Zhu, X., Sato, K., Mo, Y., Kluz, T., & Donaldson, K.
Venue
Journal of Occupational Health
Published
2003-01
Volume
45
Issue
1
Pages
23-30
ISSN
  • 1341-9145 (ISSN-L)
  • 1348-9585
OpenAlex
W2122368908
Cited by
183
References
0
FWCI
5.22
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative Toxicity of Standard Nickel and Ultrafine Nickel in Lung after Intratracheal Instillation. https://app.cochat.ai/papers/10.1539/joh.45.23
The paper
Zhang, Q., Kusaka, Y., Zhu, X., Sato, K., Mo, Y., Kluz, T., & Donaldson, K. (2003). Comparative Toxicity of Standard Nickel and Ultrafine Nickel in Lung after Intratracheal Instillation. Journal of Occupational Health. https://doi.org/10.1539/joh.45.23

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.