The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Newborn Hearing Screening: The Great Omission
Abstract
Objective. The advent of technologic improvements in assessing the hearing of newborn infants has made possible the implementation of universal newborn hearing screening. Furthermore, selective screening based on high-risk criteria fails to detect half of all infants with congenital hearing loss. Although universal screening has been recommended by the National Institutes of Health and the Joint Committee on Infant Hearing Screening, data to support this recommendation have been incomplete, and the recommendation has been seen as without solid foundation by many in the pediatrics field. This study was designed to assess the feasibility, accuracy, and cost-effectiveness of a hospital-based hearing screening program for all newborns. Methodology. Between 1992 and 1996, hospitals in Colorado with 100 or more births per year were targeted to participate in universal hearing screening of newborns. To date, 26 of 52 targeted hospitals, ranging in size from 40 to 3500 births per year, have implemented universal screening. A total of 41 796 infants were screened between 1992 and 1996. Screening was performed using automated auditory brainstem response, otoacoustic emission testing, or conventional auditory brainstem response, with follow-up testing performed on those infants who failed initial screening. Results. Of 41 796 infants screened at birth, 2709 failed initial screening, and of 1296 who have completed reevaluation, 94 have been identified with congenital sensorineural hearing loss (75 bilateral) and an additional 32 identified with conductive hearing loss (14 bilateral). The frequency of bilateral congenital hearing loss requiring amplification therefore is shown to be at least 1 in every 500 newborns. During the study period, an additional 17 children with significant hearing loss not identified until ≥18 months of age were reported voluntarily; all 17 had been born at hospitals not participating in newborn hearing screening. The false-positive rate for the screening program to date in Colorado is calculated to be 6%, but evolving technology has resulted in improvements to as low as 2%. Positive predictive value of an abnormal screen result is shown to be at least 5%, and as high as 19%, with improving technology. The sensitivity of newborn screening is demonstrated to be at or near 100%. Costs of screening are compared with other screened congenital diseases; although the true cost per child for newborn hearing screening is significantly higher than screening tests performed on blood, the much higher incidence of congenital hearing loss results in a comparable cost per case diagnosed when compared with hypothyroidism or phenylketonuria, for example. The feasibility of early intervention is demonstrated, with amplification by the use of hearing aids being the catalyst for effective treatment. Finally, the costs of screening and early intervention are compared with the monetary savings in avoiding delayed and therefore intensive therapy and intervention for children not diagnosed at birth. The true cost of screening for one newborn is shown to be between $18 and $33, with an average cost of $25 per infant. The cost per case of congenital hearing loss diagnosed is ∼$9600. A model for cost predictions and subsequent intervention savings is presented, and recovery of all screening costs is demonstrated after only 10 years of universal screening in Colorado. Conclusions. Universal newborn hearing screening is feasible, beneficial, and justified, as indicated by the frequency of the disease, the accuracy of screening tests, the ability to provide early intervention, the improved outcomes attributable to early amplification, and the recovery of all screening costs in the prevention of future intervention costs. Furthermore, the incidence of bilateral congenital hearing loss is alarming, and is, in fact, many times greater than the combined incidence of all newborn screening tests currently performed on blood samples. The demonstrated effectiveness of newborn hearing screening and the availability of early amplification and intervention support the expanding recommendation that every newborn be screened for congenital hearing loss.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early identification of hearing impairment in infants and young children
Ruben, R. J. (1993) · International Journal of Pediatric Otorhinolaryngology · doi:10.1016/0165-5876(93)90227-t · Cited by 295
Bess, F. H., & Paradise, J. L. (1994) · Pediatrics · doi:10.1542/peds.93.2.330 · Cited by 201
Desposito, F., Cho, S., Frías, J. L., Sherman, J., Wappner, R. S., & Wilson, M. G. (1996) · Cited by 62
(1996) · PEDIATRICS · doi:10.1542/peds.98.3.473 · Cited by 61
Cited by
Language of Early- and Later-identified Children With Hearing Loss
Yoshinaga-Itano, C., Sedey, A. L., Coulter, D. K., & Mehl, A. L. (1998) · Pediatrics · doi:10.1542/peds.102.5.1161 · Cited by 2,150
Self-citationJoint Committee on Infant Hearing (2007) · Pediatrics · doi:10.1542/peds.2007-2333 · Cited by 2,056
Sensorineural hearing loss in children
Smith, R. J., Bale, J. F., & White, K. R. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71047-3 · Cited by 843
Newborn and Infant Hearing Loss: Detection and Intervention
Task Force on Newborn and Infant Hearing (1999) · Pediatrics · doi:10.1542/peds.103.2.527 · Cited by 590
Speech-Language and Educational Consequences of Unilateral Hearing Loss in Children
Lieu, J. E. C. (2004) · Archives of Otolaryngology–Head & Neck Surgery · doi:10.1001/archotol.130.5.524 · Cited by 449
Unilateral Hearing Loss Is Associated With Worse Speech-Language Scores in Children
Lieu, J. E. C., Tye-Murray, N., Karzon, R. K., & Piccirillo, J. F. (2010) · Pediatrics · doi:10.1542/peds.2009-2448 · Cited by 337
Banatvala, J., & Brown, D. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15897-2 · Cited by 289
Age at Intervention for Permanent Hearing Loss and 5-Year Language Outcomes
Ching, T. Y. C., Dillon, H., Button, L., Seeto, M., Van Buynder, P., Marnane, V., Cupples, L., & Leigh, G. (2017) · Pediatrics · doi:10.1542/peds.2016-4274 · Cited by 288
Aminoglycoside-Induced Cochleotoxicity: A Review
Jiang, M., Karasawa, T., & Steyger, P. S. (2017) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2017.00308 · Cited by 261
Young, A. (2001) · Journal of Deaf Studies and Deaf Education · doi:10.1093/deafed/6.3.149 · Cited by 29
Metadata
- Authors
- Mehl, A. L., & Thomson, V.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 1998-01-01
- Volume
- 101
- Issue
- 1
- Pages
- e4-e4
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2135117966
- Cited by
- 464
- References
- 4
- FWCI
- 13.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.