The False-Positive in Universal Newborn Hearing Screening
The DOI matches its Crossref record.
Abstract
Objectives.: Concern has been raised about the frequency and subsequent emotional effect of a false-positive result during universal newborn hearing screening (UNHS). This study describes: 1) the results of 1 UNHS program and a potential method to significantly reduce the false-positive rate, and 2) the effect a false-positive result has on lasting maternal anxiety toward their children as well as their views toward UNHS in general. Methods.: A retrospective analysis was conducted using data from 5010 infants screened with an automated auditory brainstem response (ABR) at the Women's Hospital of Greensboro (WHOG) from July 6, 1998 to June 30, 1999. In addition, a structured telephone survey was given to mothers of infants who had failed the initial hearing screen (stage 1) and who had completed an outpatient rescreen (stage 2). Results.: Confirmed hearing loss occurred in non-neonatal intensive care unit infants at a rate of 1.8/1000. A false-positive rate of 1.9% occurred during stage 1 of UNHS (screening before newborn discharge). We attribute this relatively low rate to rescreening of 51% of those newborns who failed the initial screen before hospital discharge. Eighty percent of these rescreened infants passed, thus needing no additional follow-up. If we had rescreened all infants before discharge, the false-positive rate would have approached .5%. Results of the survey were reassuring with regard to lasting emotional effects of false-positive tests. Only 9% of mothers said they “treated their child differently” before outpatient rescreening, and only 14% reported any lasting anxiety after their child passed the outpatient repeat screen. Although none reached statistical significance, potential risk factors for lasting anxiety include more educated mothers, lack of understanding of UNHS, and a false-positive result in both stage 1 and stage 2. Over 90% of all mothers believed that UNHS was a good idea. Conclusions.: By rescreening all infants before hospital discharge, the false-positive rate of UNHS performed using automated ABR can be reduced to <1%. However, for the false-positive results that do occur, any long-lasting and detrimental emotional impact between mother and infant seems to be small and could be reduced even more with improved understanding about UNHS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Primary care physicians' knowledge, attitudes, and practices related to newborn hearing screening
Moeller, M. P., White, K. R., & Shisler, L. (2006) · Pediatrics · doi:10.1542/peds.2006-1008 · Cited by 142
Young, A. (2001) · Journal of Deaf Studies and Deaf Education · doi:10.1093/deafed/6.3.149 · Cited by 29
Metadata
- Authors
- Clemens, C. J., Davis, S. A., & Bailey, A. R.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2000-07-01
- Volume
- 106
- Issue
- 1
- Pages
- e7-e7
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2052568400
- Cited by
- 160
- References
- 0
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The False-Positive in Universal Newborn Hearing Screening. https://app.cochat.ai/papers/10.1542/peds.106.1.e7
- The paper
- Clemens, C. J., Davis, S. A., & Bailey, A. R. (2000). The False-Positive in Universal Newborn Hearing Screening. Pediatrics. https://doi.org/10.1542/peds.106.1.e7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.