The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Transcutaneous Bilirubin Measurement: A Multicenter Evaluation of a New Device
Abstract
Objectives.: The early discharge of neonates from hospitals makes transcutaneous measurement of total bilirubin concentration a useful tool to monitor neonatal jaundice. The objectives of this study were to determine whether 1) transcutaneous bilirubin (TcB) measurement, as performed using BiliCheck (BC), correlates with total serum bilirubin (TSB) levels, measured with standard laboratory methods and with high-pressure liquid chromatography (HPLC-B); 2) infant race, gestational age, postnatal age, or body weight interferes with the measurement of TcB levels in newborn infants; 3) the variability of the TcB measurement is comparable to the variability of TSB measurements; and 4) TcB measurements obtained from the forehead (BCF) and sternum (BCS) generate comparable results. Study Design.: Newborn infants who were <28 days and >30 weeks' gestational age and who underwent tests for TSB as part of their normal care in 6 different European hospitals were studied. A total of 210 infants were enrolled in the study, 35 at each site. Near simultaneous (within ± 30 minutes) blood collection for TSB and BCF and BCS measurements were performed. TSB levels were determined by the serum bilirubin method in use at each site, and all HPLC-B determinations were made at the same, independent laboratory. Results.: The study group consisted of 140 white, 31 Asian, 14 Hispanic, 9 African, and another 16 newborns of different races. The correlation coefficient (r) between BCF and HPLC-B was 0.890 (95% confidence interval = 0.858–0.915). BCF and BCS generated similar results (r value = 0.890 for BCF and 0.881 for BCS), even if BCS slightly overestimated (mean error = −0.04 mg/dL) and BCF slightly underestimated (mean error = 0.96 mg/dL) in comparison with HPLC-B. Analysis of covariance demonstrated that BC accuracy was independent of race, birth weight, gestational age, and postnatal age of the newborn. Receiver operating characteristic curves were evaluated for BCF and TSB, each compared with HPLC-B. With the use of a cutoff point for HPLC-B of 13 mg/dL (222 μmol/L) and a cutoff of 11 mg/dL on the BCF and TSB, similar sensitivity/specificity (93%/73% for BCF, 95%/76% for TSB) were observed. The use of a cutoff point for HPLC-B of 17 mg/dL (290 μmol/L) and 14 mg/dL (240 μmol/L) for BCF and TSB also produced similar sensitivity/specificity (90%/87% for the BC and 87%/83% for TSB). Conclusions.: Because the correlation coefficient for HPLC-B and BCF is very similar to that found for HPLC-B and laboratory TSB, BC could be used not only as a screening device but also as a reliable substitute of TSB determination. At higher levels of TSB, in which phototherapy and/or exchange transfusion might be considered, BC performed slightly better than the laboratory. The accuracy and precision of the TcB measurement in this study was observed to be comparable to the standard of care laboratory test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Bhutani, V. K., Johnson, L., & Sivieri, E. M. (1999) · Pediatrics · doi:10.1542/peds.103.1.6 · Cited by 894
Bhutani, V. K., Gourley, G. R., Adler, S., Kreamer, B., Dalin, C., & Johnson, L. H. (2000) · Pediatrics · doi:10.1542/peds.106.2.e17 · Cited by 417
Self-citationLength of Stay, Jaundice, and Hospital Readmission
Maisels, M. J., & Kring, E. (1998) · Pediatrics · doi:10.1542/peds.101.6.995 · Cited by 335
Yamanouchi, I., Yamauchi, Y., & Igarashi, I. (1980) · Pediatrics · doi:10.1542/peds.65.2.195 · Cited by 185
The Safety of Newborn Early Discharge: The Washington State Experience
Liu, L. L. (1997) · JAMA · doi:10.1001/jama.1997.03550040049036 · Cited by 149
Edmonson, M. B. (1997) · JAMA · doi:10.1001/jama.1997.03550040055037 · Cited by 128
Safety of newborn early discharge.
Lagace, E. (1997) · PubMed · Cited by 122
Breast Milk Jaundice in the Newborn
Schneider, A. (1986) · JAMA · doi:10.1001/jama.1986.03370230076034 · Cited by 117
Noninvasive Estimation of Serum Bilirubin
Tayaba, R., Gribetz, D., Gribetz, I., & Holzman, I. R. (1998) · PEDIATRICS · doi:10.1542/peds.102.3.e28 · Cited by 81
Cited by
Kemper, A. R., Newman, T. B., Slaughter, J. L., Maisels, M. J., Watchko, J. F., Downs, S. M., Grout, R. W., Bundy, D. G., Stark, A. R., Bogen, D. L., et al. (2022) · Pediatrics · doi:10.1542/peds.2022-058859 · Cited by 577
Diagnostic criteria and contributors to Gilbert’s syndrome
Wagner, K.-H., Shiels, R. G., Lang, C. A., Seyed Khoei, N., & Bulmer, A. C. (2018) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1428526 · Cited by 138
Point-of-care testing: where is the evidence? A systematic survey
Pecoraro, V., Germagnoli, L., & Banfi, G. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0386 · Cited by 56
Metadata
- Authors
- Rubaltelli, F. F., Gourley, G. R., Loskamp, N., Modi, N., Roth-Kleiner, M., Sender, A., & Vert, P.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2001-06-01
- Volume
- 107
- Issue
- 6
- Pages
- 1264-1271
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W1998313438
- Cited by
- 264
- References
- 12
- FWCI
- 12.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transcutaneous Bilirubin Measurement: A Multicenter Evaluation of a New Device. https://app.cochat.ai/papers/10.1542/peds.107.6.1264
- The paper
- Rubaltelli, F. F., Gourley, G. R., Loskamp, N., Modi, N., Roth-Kleiner, M., Sender, A., & Vert, P. (2001). Transcutaneous Bilirubin Measurement: A Multicenter Evaluation of a New Device. Pediatrics. https://doi.org/10.1542/peds.107.6.1264
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.