Breath-Holding Spells Associated With Significant Bradycardia: Successful Treatment With Permanent Pacemaker Implantation
The DOI matches its Crossref record.
Abstract
Objective.: To determine whether children with pallid breath-holding spells associated with bradycardia can be treated safely and successfully with permanent pacemaker implantation. Methods.: The records of pediatric patients who had apparent breath-holding spells and associated bradycardia and were treated with permanent pacemaker implantation were reviewed. Results.: Ten pediatric patients with apparent breath-holding spells associated with bradycardia were treated with a permanent ventricular demand pacemaker at the Mayo Clinic between 1985 and 1995. Patients had onset of symptoms between ages 6 days and 12 months and presented for evaluation between ages 12 months and 5 years. Duration of spells was 15 seconds to 10 minutes. Medications to prevent spells were unsuccessful. Electrocardiograms documented asystolic pauses of 1.7 to 24 seconds (mean: 11.9 seconds). Permanent ventricular demand pacemakers were implanted at 10 months to 5 years of age (median: 14.5 months): 9 endocardial and 1 epicardial. Three patients required pacemaker revision. At follow-up of 38 to 170 months (median: 65.5), 5 patients had complete resolution of spells, 2 had only mild color change without loss of consciousness or seizure activity, and 3 continued to have minor brief spells. Conclusions.: Permanent pacemaker therapy for children with pallid breath-holding spells associated with severe bradycardia is safe, efficacious, and warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Self-citationWriting Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Self-citationEpstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Self-citationTracy, C. M., Epstein, A. E., Darbar, D., DiMarco, J. P., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P. E., Link, M. S., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 732
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 552
Self-citation
Metadata
- Authors
- Kelly, A. M., Porter, C.-B. J., McGoon, M. D., Espinosa, R. E., Osborn, M. J., & Hayes, D. L.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2001-09-01
- Volume
- 108
- Issue
- 3
- Pages
- 698-702
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2049835751
- Cited by
- 120
- References
- 0
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Breath-Holding Spells Associated With Significant Bradycardia: Successful Treatment With Permanent Pacemaker Implantation. https://app.cochat.ai/papers/10.1542/peds.108.3.698
- The paper
- Kelly, A. M., Porter, C.-B. J., McGoon, M. D., Espinosa, R. E., Osborn, M. J., & Hayes, D. L. (2001). Breath-Holding Spells Associated With Significant Bradycardia: Successful Treatment With Permanent Pacemaker Implantation. Pediatrics. https://doi.org/10.1542/peds.108.3.698
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.