The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Randomized, Controlled Trial Comparing Two Different Continuous Positive Airway Pressure Systems for the Successful Extubation of Extremely Low Birth Weight Infants
Abstract
Objective. To determine whether the use of the Infant Flow continuous positive airway pressure (IF CPAP) system reduces the rate of extubation failure among extremely low birth weight (ELBW) infants (infants with birth weight <1000 g) when compared with conventional CPAP delivered with a conventional ventilator and nasal prongs. Methods. A prospective, unmasked, randomized, controlled clinical trial was conducted in 162 eligible intubated ELBW infants who were hospitalized in 2 intensive care nurseries in Winston-Salem, North Carolina, between July 1997 and November 2000. Successful extubation was defined as no need for reintubation for any reason for at least 7 days after the first extubation attempt. Results. The individual extubation success rates were 61.9% (52 of 84) in the conventional CPAP group and 61.5% (48 of 78) in the IF CPAP group. There were no significant differences in the extubation success rate in any birth weight subset between the 2 cohorts. The most common cause of extubation failure was apnea/bradycardia. Infants who were randomized to IF CPAP had fewer days on supplemental O2 and shorter hospital stays. Conclusions. Extubation failure is a common problem, occurring in nearly 40% of ELBW infants who require mechanical ventilation. IF CPAP was as effective but no more effective than conventional CPAP in preventing extubation failure among ELBW infants. New strategies are needed to identify predictors of extubation success and to treat apnea/bradycardia, the most common cause of extubation failure, thereby reducing the likelihood of prolonged intubation in this high-risk cohort of premature infants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04337-3 · Cited by 5,373
Cited by
De Paoli, A. G., Davis, P. G., Argus, B., & Jackson, H. D. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002977.pub2 · Cited by 298
Metadata
- Authors
- Stefanescu, B. M., Murphy, W. P., Hansell, B. J., Fuloria, M., Morgan, T. M., & Aschner, J. L.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2003-11-01
- Volume
- 112
- Issue
- 5
- Pages
- 1031-1038
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2151895387
- Cited by
- 171
- References
- 1
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Randomized, Controlled Trial Comparing Two Different Continuous Positive Airway Pressure Systems for the Successful Extubation of Extremely Low Birth Weight Infants. https://app.cochat.ai/papers/10.1542/peds.112.5.1031
- The paper
- Stefanescu, B. M., Murphy, W. P., Hansell, B. J., Fuloria, M., Morgan, T. M., & Aschner, J. L. (2003). A Randomized, Controlled Trial Comparing Two Different Continuous Positive Airway Pressure Systems for the Successful Extubation of Extremely Low Birth Weight Infants. Pediatrics. https://doi.org/10.1542/peds.112.5.1031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.