Heart Rate Characteristics and Laboratory Tests in Neonatal Sepsis
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objective. The evaluation of an infant for suspected sepsis often includes obtaining blood for laboratory tests. The shortcomings of the current practice are that the infant has to appear clinically ill for the diagnosis to be entertained, and the conventional laboratory tests are invasive. We have found that the clinical diagnosis of neonatal sepsis is preceded by abnormal heart rate characteristics (HRC) of reduced variability and transient decelerations, and we have devised a predictive HRC monitoring strategy based on multivariable logistic regression analysis that was developed at one tertiary care NICU and validated at another. We hypothesized that HRC monitoring, which is continuous and noninvasive, might be an adjunct to conventional laboratory tests in the diagnosis of neonatal sepsis. The objective of this study was to test the hypothesis that HRC monitoring adds information to conventional laboratory tests in diagnosing neonatal sepsis. Methods. We prospectively collected heart rate data in 678 consecutive infants who stayed >7 days in the University of Virginia NICU from July 1999 to July 2003. We prospectively measured HRC and noted 149 episodes of sepsis with positive blood cultures for which data were available in 137. We obtained all laboratory test results for ratio of immature to total neutrophil count, white blood cell count, glucose, platelet count, HCO3, arterial partial pressure of carbon dioxide, and pH. We tested hypotheses using multivariable logistic regression modeling adjusted for repeated measures. Results. We found that the HRC index, which was available 92% of the time, was highly significantly associated with sepsis (receiver-operating characteristic [ROC] area: 0.73). The ratio of immature to total neutrophil count, white blood cell count (available 4%–8% of the time, usually around the time of suspected sepsis), and blood glucose and pH (available 28% and 38% of the time) were also significantly associated with sepsis (ROC area: 0.75). HRC and laboratory values added independent information to each other, and a predictive model using all significant variables had ROC area of 0.82. Conclusions. HRC monitoring adds independent information to laboratory tests in the diagnosis of culture-positive neonatal sepsis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880
Self-citation
Cited by
Moorman, J. R., Carlo, W. A., Kattwinkel, J., Schelonka, R. L., Porcelli, P. J., Navarrete, C. T., Bancalari, E., Aschner, J. L., Whit Walker, M., Perez, J. A., et al. (2011) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2011.06.044 · Cited by 369
Self-citationTime for a Neonatal-Specific Consensus Definition for Sepsis
Wynn, J. L., Wong, H. R., Shanley, T. P., Bizzarro, M. J., Saiman, L., & Polin, R. A. (2014) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000000157 · Cited by 303
Medical decision support using machine learning for early detection of late-onset neonatal sepsis
Mani, S., Ozdas, A., Aliferis, C., Varol, H. A., Chen, Q., Carnevale, R., Chen, Y., Romano-Keeler, J., Nian, H., & Weitkamp, J.-H. (2014) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2013-001854 · Cited by 196
Heart Rate Characteristics and Clinical Signs in Neonatal Sepsis
Griffin, M. P., Lake, D. E., O'Shea, T. M., & Moorman, J. R. (2007) · Pediatric Research · doi:10.1203/01.pdr.0000252438.65759.af · Cited by 168
“Laboratory tests such as the I:T ratio add predictive information independent of the HRC index (19).”
BackgroundMethodResultSelf-citationAhmad, S., Tejuja, A., Newman, K. D., Zarychanski, R., & Seely, A. J. (2009) · Critical Care · doi:10.1186/cc8132 · Cited by 151
“In one of the clinical trials, data were collected from 678 infants who spent more than 7 days in the University of Virginia Neonatal ICU from July 1999 to July 2003 [44].”
Method
Metadata
- Authors
- Griffin, M. P., Lake, D. E., & Moorman, J. R.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2005-04-01
- Volume
- 115
- Issue
- 4
- Pages
- 937-941
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2166833790
- Cited by
- 136
- References
- 1
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.