The DOI matches its Crossref record.
Incidence and Nature of Adverse Events During Pediatric Sedation/Anesthesia for Procedures Outside the Operating Room: Report From the Pediatric Sedation Research Consortium
Abstract
OBJECTIVE. We sought to use a large database of prospectively collected data on pediatric sedation and/or anesthesia for diagnostic and therapeutic procedures to delineate the nature and the frequency of adverse events that are associated with sedation/anesthesia care for procedures that are performed outside the operating room in children. METHODS. Data were collected by the Pediatric Sedation Research Consortium, a collaborative group of 35 institutions that are dedicated to improving sedation/anesthesia care for children internationally. Members prospectively enrolled consecutive patients who were receiving sedation or anesthesia for procedures. Data on demographics, primary illness, coexisting illness, procedure performed, medications used, outcomes, airway interventions, and adverse events were collected and reported on a Web-based data collection tool. RESULTS. A total of 26 institutions submitted data on 30037 sedation/anesthesia encounters during the study period from July 1, 2004, to November 15, 2005. Serious adverse events were rare in the institutions involved in this study; there were no deaths. Cardiopulmonary resuscitation was required once. Less serious events were more common with O2 desaturation below 90% for >30 seconds, occurring 157 times per 10000 sedations. Stridor and laryngospasm both occurred in 4.3 per 10000 sedations. Unexpected apnea, excessive secretions, and vomiting had frequencies of 24, 41.6, and 47.2 per 10000 encounters, respectively. CONCLUSIONS. Our data indicate that pediatric sedation/anesthesia for procedures outside the operating room is unlikely to yield serious adverse outcomes in a collection of institutions with highly motivated and organized sedation services. However, the safety of this practice depends on the systems' ability to manage less serious events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cravero, J. P., Beach, M. L., Blike, G. T., Gallagher, S. M., & Hertzog, J. H. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31818fc334 · Cited by 607
Self-citationde Bie, H. M. A., Boersma, M., Wattjes, M. P., Adriaanse, S., Vermeulen, R. J., Oostrom, K. J., Huisman, J., Veltman, D. J., & Delemarre-Van de Waal, H. A. (2010) · European Journal of Pediatrics · doi:10.1007/s00431-010-1181-z · Cited by 245
Farahmand, F. K., Duffy, S. N., Tailor, M. A., DuBois, D. L., Lyon, A. L., Grant, K. E., Zarlinski, J. C., Masini, O., Zander, K. J., & Nathanson, A. M. (2012) · Clinical Psychology Science and Practice · doi:10.1111/j.1468-2850.2012.01283.x · Cited by 42
Sedation and analgesia for procedures in the pediatric emergency room
Ramalho, C. E., Bretas, P. M. C., Schvartsman, C., & Reis, A. G. (2017) · Jornal de Pediatria · doi:10.1016/j.jped.2017.07.009 · Cited by 35
Sedation in the emergency department: A complex and multifactorial challenge
Kennedy, R. M. (2015) · Pediatric Sedation Outside of the Operating Room · doi:10.1007/978-1-4939-1390-9_19 · Cited by 4
Metadata
- Authors
- Cravero, J. P., Blike, G. T., Beach, M., Gallagher, S. M., Hertzog, J. H., Havidich, J. E., Gelman, B., & and the Pediatric Sedation Research Consortium
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2006-09-01
- Volume
- 118
- Issue
- 3
- Pages
- 1087-1096
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2119051192
- Cited by
- 468
- References
- 0
- FWCI
- 21.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Incidence and Nature of Adverse Events During Pediatric Sedation/Anesthesia for Procedures Outside the Operating Room: Report From the Pediatric Sedation Research Consortium. https://app.cochat.ai/papers/10.1542/peds.2006-0313
- The paper
- Cravero, J. P., Blike, G. T., Beach, M., Gallagher, S. M., Hertzog, J. H., Havidich, J. E., Gelman, B., & and the Pediatric Sedation Research Consortium. (2006). Incidence and Nature of Adverse Events During Pediatric Sedation/Anesthesia for Procedures Outside the Operating Room: Report From the Pediatric Sedation Research Consortium. Pediatrics. https://doi.org/10.1542/peds.2006-0313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.