Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 343

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Adverse Events in the Neonatal Intensive Care Unit: Development, Testing, and Findings of an NICU-Focused Trigger Tool to Identify Harm in North American NICUs

Sharek, Paul J., Horbar, Jeffrey D., Mason, Wilbert, Bisarya, Hema, Thurm, Cary W., Suresh, Gautham, Gray, James E., Edwards, William H., Goldmann, Donald, Classen, David · 2006 · Pediatrics

Abstract

OBJECTIVES. Currently there are few practical methods to identify and measure harm to hospitalized children. Patients in NICUs are at high risk and warrant a detailed assessment of harm to guide patient safety efforts. The purpose of this work was to develop a NICU-focused tool for adverse event detection and to describe the incidence of adverse events in NICUs identified by this tool. METHODS. A NICU-focused trigger tool for adverse event detection was developed and tested. Fifty patients from each site with a minimum 2-day NICU stay were randomly selected. All adverse events identified using the trigger tool were evaluated for severity, preventability, ability to mitigate, ability to identify the event earlier, and presence of associated occurrence report. Each trigger, and the entire tool, was evaluated for positive predictive value. Study chart reviewers, in aggregate, identified 88.0% of all potential triggers and 92.4% of all potential adverse events. RESULTS. Review of 749 randomly selected charts from 15 NICUs revealed 2218 triggers or 2.96 per patient, and 554 unique adverse events or 0.74 per patient. The positive predictive value of the trigger tool was 0.38. Adverse event rates were higher for patients <28 weeks' gestation and <1500 g birth weight. Fifty-six percent of all adverse events were deemed preventable; 16% could have been identified earlier, and 6% could have been mitigated more effectively. Only 8% of adverse events were identified in existing hospital-based occurrence reports. The most common adverse events identified were nosocomial infections, catheter infiltrates, and abnormal cranial imaging. CONCLUSIONS. Adverse event rates in the NICU setting are substantially higher than previously described. Many adverse events resulted in permanent harm and the majority were classified as preventable. Only 8% were identified using traditional voluntary reporting methods. Our NICU-focused trigger tool appears efficient and effective at identifying adverse events.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1542/peds.2006-0565

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 343

Metadata

Authors
Sharek, P. J., Horbar, J. D., Mason, W., Bisarya, H., Thurm, C. W., Suresh, G., Gray, J. E., Edwards, W. H., Goldmann, D., & Classen, D.
Venue
Pediatrics
Published
2006-10-01
Volume
118
Issue
4
Pages
1332-1340
ISSN
  • 0031-4005 (ISSN-L)
  • 1098-4275
OpenAlex
W2152766444
Cited by
343
References
22
FWCI
21.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adverse Events in the Neonatal Intensive Care Unit: Development, Testing, and Findings of an NICU-Focused Trigger Tool to Identify Harm in North American NICUs. https://app.cochat.ai/papers/10.1542/peds.2006-0565
The paper
Sharek, P. J., Horbar, J. D., Mason, W., Bisarya, H., Thurm, C. W., Suresh, G., Gray, J. E., Edwards, W. H., Goldmann, D., & Classen, D. (2006). Adverse Events in the Neonatal Intensive Care Unit: Development, Testing, and Findings of an NICU-Focused Trigger Tool to Identify Harm in North American NICUs. Pediatrics. https://doi.org/10.1542/peds.2006-0565

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.