The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Systematic Intervention to Reduce Central Line–Associated Bloodstream Infection Rates in a Pediatric Cardiac Intensive Care Unit
Abstract
OBJECTIVE. Our goal was to determine whether an intervention involving staff education, increased awareness, and practice changes would decrease central line–associated bloodstream infection rates in a pediatric cardiac ICU. METHODS. A retrospective, interventional study using an interrupted time-series design was conducted to compare central line–associated bloodstream infection rates during 3 time periods for all patients admitted to our pediatric cardiac ICU between April 1, 2004, and December 31, 2006. During the preintervention period (April 2004 to December 2004), a committee was convened to track and prevent nosocomial infections. Pretesting demonstrated knowledge deficits regarding nosocomial infection prevention, and educational tools were developed. During the partial intervention period (January 2005 to March 2006), a comprehensive central line–associated bloodstream infection prevention initiative was implemented, including establishment of a unit-based infection control nurse position, education for physicians and nurses, real-time feedback on central line–associated bloodstream infection data, implementation of central venous line insertion, access, and maintenance bundles, and introduction of daily goal sheets on rounds that emphasized timely central venous line removal. Central line–associated bloodstream infection rates in the preintervention, partial intervention, and full intervention (April 2006 to December 2006) periods were compared. RESULTS. The estimated mean preintervention central line–associated bloodstream infection rate was 7.8 infections per 1000 catheter-days, which decreased to 4.7 infections per 1000 catheter-days in the partial intervention period and 2.3 infections per 1000 catheter-days in the full intervention period. The preintervention central line–associated bloodstream infection rate was significantly higher than the median rate of 3.5 infections per 1000 catheter-days for multidisciplinary PICUs reporting to the National Healthcare Safety Network. During the full intervention period, our central line–associated bloodstream infection rate was lower than this pediatric benchmark, although statistical significance was not achieved. CONCLUSIONS. A multidisciplinary, evidence-based initiative resulted in a significant reduction in central line–associated bloodstream infections in our pediatric cardiac ICU.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Intervention to Decrease Catheter-Related Bloodstream Infections in the ICU
Pronovost, P., Needham, D., Berenholtz, S., Sinopoli, D., Chu, H., Cosgrove, S., Sexton, B., Hyzy, R., Welsh, R., Roth, G., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061115 · Cited by 4,387
Segmented regression analysis of interrupted time series studies in medication use research
Wagner, A. K., Soumerai, S. B., Zhang, F., & Ross-Degnan, D. (2002) · Journal of Clinical Pharmacy and Therapeutics · doi:10.1046/j.1365-2710.2002.00430.x · Cited by 3,279
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir138 · Cited by 560
Schlapbach, L. J., Aebischer, M., Adams, M., Natalucci, G., Bonhoeffer, J., Latzin, P., Nelle, M., Bucher, H. U., Latal, B., & the Swiss Neonatal Network and Follow-Up Group (2011) · Pediatrics · doi:10.1542/peds.2010-3338 · Cited by 360
Decreasing PICU Catheter-Associated Bloodstream Infections: NACHRI's Quality Transformation Efforts
Miller, M. R., Griswold, M., Harris, J. M., Yenokyan, G., Huskins, W. C., Moss, M., Rice, T. B., Ridling, D., Campbell, D., Margolis, P., et al. (2010) · Pediatrics · doi:10.1542/peds.2009-1382 · Cited by 348
Metadata
- Authors
- Costello, J. M., Morrow, D. F., Graham, D. A., Potter-Bynoe, G., Sandora, T. J., & Laussen, P. C.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2008-05-01
- Volume
- 121
- Issue
- 5
- Pages
- 915-923
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W1987575801
- Cited by
- 205
- References
- 2
- FWCI
- 35.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Systematic Intervention to Reduce Central Line–Associated Bloodstream Infection Rates in a Pediatric Cardiac Intensive Care Unit. https://app.cochat.ai/papers/10.1542/peds.2007-1577
- The paper
- Costello, J. M., Morrow, D. F., Graham, D. A., Potter-Bynoe, G., Sandora, T. J., & Laussen, P. C. (2008). Systematic Intervention to Reduce Central Line–Associated Bloodstream Infection Rates in a Pediatric Cardiac Intensive Care Unit. Pediatrics. https://doi.org/10.1542/peds.2007-1577
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.