Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 190

The DOI matches its Crossref record.

Airway Obstruction During Mask Ventilation of Very Low Birth Weight Infants During Neonatal Resuscitation

Finer, Neil N., Rich, Wade, Wang, Casey, Leone, Tina · 2009 · Pediatrics

Abstract

OBJECTIVES. The delivery of adequate but not excessive ventilation remains one of the most common problems encountered during neonatal resuscitation, especially in the very low birth weight infant. Our observations suggest that airway obstruction is a common occurrence after delivery of such infants, and we use colorimetric carbon dioxide detectors during bag-and-mask resuscitation to assist in determining whether the airway was patent. We reviewed our experience to determine the frequency of the occurrence of recognizable airway obstruction during resuscitation of very low birth weight infants. METHODS AND PATIENTS. The previous prospective trial randomly assigned preterm infants <32 weeks' gestation to resuscitation with either room air or 100% oxygen using pulse oximetry. Colorimetric carbon dioxide detectors were used to assist with bag-and-mask ventilation and to confirm intubation. From the video recordings, the number of positive pressure breaths without a color change in the detector until the breaths were associated with an unequivocal color change was counted as obstructed breaths. From the analog tracings, the number of breaths that had a peak pressure plateau of ≥0.2 second and were not associated with a color change was recorded as the number of obstructed breaths. RESULTS. None of the studied infants required cardiopulmonary resuscitation or received epinephrine, and all were judged to have an effective circulation during resuscitation. Six of the 24 infants enrolled in the trial received only continuous positive airway pressure. The remaining 18 infants received a median of 14 obstructed breaths (range: 4–37 breaths) delivered over a mean and median interval of 56.7 and 45.0 seconds, respectively (range: 10.0–220.0 seconds). A subgroup of 11 infants was analyzed using airway-pressure data. The target peak inspiratory pressure was 30 cm H2O. Ten of these 11 infants had obstructed breaths as defined by no change in the PediCap despite reaching the target pressure for ≥0.2 second. CONCLUSION. Airway obstruction occurs in the majority of the very low birth weight infants who receive ventilation with a face mask during resuscitation and the use of a colorimetric detector can facilitate its recognition and management.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1542/peds.2008-0560

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 190

Metadata

Authors
Finer, N. N., Rich, W., Wang, C., & Leone, T.
Venue
Pediatrics
Published
2009-03-01
Volume
123
Issue
3
Pages
865-869
ISSN
  • 0031-4005 (ISSN-L)
  • 1098-4275
OpenAlex
W2154619925
Cited by
190
References
0
FWCI
12.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Airway Obstruction During Mask Ventilation of Very Low Birth Weight Infants During Neonatal Resuscitation. https://app.cochat.ai/papers/10.1542/peds.2008-0560
The paper
Finer, N. N., Rich, W., Wang, C., & Leone, T. (2009). Airway Obstruction During Mask Ventilation of Very Low Birth Weight Infants During Neonatal Resuscitation. Pediatrics. https://doi.org/10.1542/peds.2008-0560

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.