The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Radiation Exposure in 212 Very Low and Extremely Low Birth Weight Infants
Abstract
OBJECTIVE: We determined the frequency and estimated effective radiation dose (E) from conventional diagnostic radiographs for infants who had birth weight of ≤1500 g (very low birth weight [VLBW] infants) and were treated in a NICU. METHODS: Entrance skin doses were experimentally measured for all standard weight-dependent exposure settings. For each radiograph in the radiologic file, the exposed area on the film was measured manually. Together with clinical data obtained from the Vermont Oxford Network, medical charts, and radiologic files, we estimated E. E values per radiograph and per child were compared with recommended reference values and annual natural background radiation (NBR). We used reference data to estimate the risk for radiation-induced cancers. RESULTS: Of 212 VLBW infants, 194 required at least 1 conventional radiograph. Measured entrance skin dose varied between 11.8 and 15.0 μGy. Calculated E received was 16 microsievert (μSv; median) per radiograph and 71.5 μSv (median) per infant for the whole stay. Infants with birth weight ≤750 g, length of stay ≥16 weeks, congenital malformations, or oxygen dependence for ≥36 weeks were at risk for high numbers of radiographs and high radiation dose. Compared with the annual NBR, the median of 4 radiographs per infant contributes 12 days of NBR. We estimated that only 1 of 60000 NICU-treated VLBW infants will develop a fatal malignancy up to 15 years of age. CONCLUSIONS: We found that NICU-treated VLBW infants had low radiation exposure compared with the annual NBR.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“a modality required for 90% of low–birth weight neonates (26).”
From Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care (2019) · cites this paper as [26]
Citations
Cites
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,868
International Commission on Radiological Protection
(1969) · Radiology · doi:10.1148/93.6.1298 · Cited by 2,150
The United Nations Scientific Committee on the Effects of Atomic Radiation
(1965) · Nature · doi:10.1038/206014c0 · Cited by 1,636
Annual Summary of Vital Statistics: 2006
Martin, J. A., Kung, H.-C., Mathews, T. J., Hoyert, D. L., Strobino, D. M., Guyer, B., & Sutton, S. R. (2008) · Pediatrics · doi:10.1542/peds.2007-3753 · Cited by 759
Effect of Very Low Birth Weight and Subnormal Head Size on Cognitive Abilities at School Age
Hack, M., Breslau, N., Weissman, B., Aram, D., Klein, N., & Borawski, E. (1991) · New England Journal of Medicine · doi:10.1056/nejm199107253250403 · Cited by 503
McCollough, C. H., & Schueler, B. A. (2000) · Medical Physics · doi:10.1118/1.598948 · Cited by 291
Hart, D. B., Jones, D., & Wall, B. F. (1994) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 275
The Vermont Oxford Network: Evidence-Based Quality Improvement for Neonatology
Horbar, J. D. (1999) · PEDIATRICS · doi:10.1542/peds.103.se1.350 · Cited by 237
Shu, X. O., Potter, J. D., Linet, M. S., Severson, R. K., Han, D., Kersey, J. H., Neglia, J. P., Trigg, M. E., & Robison, L. L. (2002) · PubMed · Cited by 128
Radiation dose quantities and risk in neonates in a special care baby unit
Armpilia, C., Fife, I. A. J., & Croasdale, P. L. (2002) · British Journal of Radiology · doi:10.1259/bjr.75.895.750590 · Cited by 92
Research works printed but not linked: 3
- Schneider K. Radiation protection and quality assurance in pediatric radiology. In: Schuster W, Färber D, eds. Radiography: In Infancy & Childhood. Germany: Springer; 1996:19–31Vol 1. Berlin
- Zeiler M, Weisbach M, Weigl A, et al. Patient exposure and radiographic technique in neonatal chest radiography: a survey in Germany. Eur Radiol Suppl. 1993;3:85
- Meinert R, Kaletsch U, Kaatsch P, Schuz J, Michaelis J. Associations between childhood cancer and ionizing radiation: results of a population-based case-control study in Germany. Cancer Epidemiol Biomarkers Prev. 1999;8(9):793–799
Cited by
Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807
“The EES eliminates radio-opaque wires, thereby improving evaluation by x-ray imaging, a modality required for 90% of low–birth weight neonates (26).”
BackgroundComparison of ultrasound and X-ray in determining the position of umbilical venous catheters
Michel, F., Brevaut‐Malaty, V., Pasquali, R., Thomachot, L., Vialet, R., Hassid, S. A., Nicaise, C., Martin, C., & Panuel, M. (2011) · Resuscitation · doi:10.1016/j.resuscitation.2011.11.026 · Cited by 121
The Predictive Value of Lung Ultrasound Scores in Developing Bronchopulmonary Dysplasia
Ojembarrena, A. A., Serna‐Guerediaga, I., Aldecoa‐Bilbao, V., Gregorio‐Hernández, R., Alonso‐Quintela, P., Concheiro‐Guisán, A., Ramos-Rodríguez, A., Heras-Martín, M. D. L., Fernández, L. R., & Erroz, I. O. (2021) · CHEST Journal · doi:10.1016/j.chest.2021.02.066 · Cited by 87
Blank, D. A., Kamlin, C. O. F., Rogerson, S. R., Fox, L. M., Springer, L., Kane, S. C., Polglase, G. R., Hooper, S. B., & Davis, P. G. (2017) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/archdischild-2017-312818 · Cited by 84
Diagnostic ionizing radiation exposure in premature patients
Scott, M. V., Fujii, A. M., Behrman, R. H., & Dillon, J. E. (2014) · Journal of Perinatology · doi:10.1038/jp.2013.141 · Cited by 59
Metadata
- Authors
- Puch-Kapst, K., Juran, R., Stoever, B., & Wauer, R. R.
- Affiliations
- Charité – Universitätsmedizin Berlin (DE)
- Institute of Radiology
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2009-12-01
- Volume
- 124
- Issue
- 6
- Pages
- 1556-1564
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W1987702684
- Cited by
- 71
- References
- 35
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 6 · 2023: 4 · 2022: 4 · 2021: 8 · 2020: 6 · 2019: 7 · 2018: 7 · 2017: 7 · 2016: 1 · 2015: 2 · 2014: 4 · 2013: 7 · 2012: 1
- FWCI
- 1.01
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- PEDIATRICS (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Keywords
- radiation exposure, very low birth weight infants, extremely low birth weight infants, neonatal intensive care unit, diagnostic radiography, entrance skin dose, effective dose, natural background radiation, radiation-induced cancer risk, congenital malformations, oxygen dependence, length of hospital stay
- MeSH terms
- Body Burden, Female, Humans, Infant, Newborn, Intensive Care Units, Neonatal, Length of Stay, Male, Neoplasms, Radiation-Induced, Radiation Dosage, Radiography, Radiometry, Risk Factors, Utilization Review, Cohort Studies, Infant, Very Low Birth Weight, Infant, Extremely Low Birth Weight
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiation Exposure in 212 Very Low and Extremely Low Birth Weight Infants. https://app.cochat.ai/papers/10.1542/peds.2008-1028
- The paper
- Puch-Kapst, K., Juran, R., Stoever, B., & Wauer, R. R. (2009). Radiation Exposure in 212 Very Low and Extremely Low Birth Weight Infants. Pediatrics. https://doi.org/10.1542/peds.2008-1028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.