Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 340

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Reference Ranges for Hematocrit and Blood Hemoglobin Concentration During the Neonatal Period: Data From a Multihospital Health Care System

Jopling, Jeffery, Henry, Erick, Wiedmeier, Susan E., Christensen, Robert D.·2009·Pediatrics

Abstract

OBJECTIVE. “Reference ranges” are developed when it is impossible or inappropriate to establish “normal ranges” by drawing blood on healthy normal volunteers. Reference ranges for the hematocrit and the blood hemoglobin concentration of newborn infants have previously been reported from relatively small sample sizes by using measurement methods that now are considered outmoded. METHODS. We sought to develop reference ranges for hematocrit and hemoglobin during the neonatal period (28 days) by using very large sample sizes and modern hematology analyzers, accounting for gestational and postnatal age and gender. Data were assembled from a multihospital health care system after exclusion of patients with a high likelihood of an abnormal value and those who were receiving blood transfusions. RESULTS. During the interval from 22 to 40 weeks' gestation, the hematocrit and blood hemoglobin concentration increased approximately linearly. For every week advance in gestational age, the hematocrit increased by 0.64% and the hemoglobin concentration increased by 0.21 g/dL. No difference was seen on the basis of gender. During the 4-hour interval after birth, hematocrit/hemoglobin values of late preterm and term neonates (35–42 weeks' gestation) increased by 3.6% ± 0.5% (mean ± SD), those of neonates of 29 to 34 weeks' gestation remained unchanged, and those of <29 weeks' gestation decreased by 6.0% ± 0.3%. During the first 28 days after birth, an approximately linear decrease in hematocrit/hemoglobin occurred. CONCLUSIONS. The figures presented herein describe reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period, accounting for gestational and postnatal age.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1542/peds.2008-2654

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 340

Metadata

Authors
Jopling, J., Henry, E., Wiedmeier, S. E., & Christensen, R. D.
Venue
Pediatrics
Published
2009-02-01
Volume
123
Issue
2
Pages
e333-e337
ISSN
  • 0031-4005 (ISSN-L)
  • 1098-4275
OpenAlex
W2152279809
Cited by
340
References
6
FWCI
9.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reference Ranges for Hematocrit and Blood Hemoglobin Concentration During the Neonatal Period: Data From a Multihospital Health Care System. https://app.cochat.ai/papers/10.1542/peds.2008-2654
The paper
Jopling, J., Henry, E., Wiedmeier, S. E., & Christensen, R. D. (2009). Reference Ranges for Hematocrit and Blood Hemoglobin Concentration During the Neonatal Period: Data From a Multihospital Health Care System. Pediatrics. https://doi.org/10.1542/peds.2008-2654

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.