Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 169

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Diagnostic Performance of Ultrasound in Nonpalpable Cryptorchidism: A Systematic Review and Meta-analysis

Open access
Tasian, Gregory E., Copp, Hillary L. · 2011 · Pediatrics

Abstract

CONTEXT: Ultrasound is frequently obtained during the presurgical evaluation of boys with nonpalpable undescended testes, but its clinical utility is uncertain. OBJECTIVE: To determine the diagnostic performance of ultrasound in localizing nonpalpable testes in pediatric patients. METHODS: English-language articles were identified by searching Medline, Embase, and the Cochrane Library. We included studies of subjects younger than 18 years who had preoperative ultrasound evaluation for nonpalpable testes and whose testis position was determined by surgery. Data on testis location determined by ultrasound and surgery were extracted by 2 independent reviewers, from which ultrasound performance characteristics (true-positives, false-positives, false-negatives, and true-negatives) were derived. Meta-analysis of 12 studies (591 testes) was performed by using a random-effects regression model; composite estimates of sensitivity, specificity, and likelihood ratios were calculated. RESULTS: Ultrasound has a sensitivity of 45% (95% confidence interval [CI]: 29–61) and a specificity of 78% (95% CI: 43–94). The positive and negative likelihood ratios are 1.48 (95% CI: 0.54–4.03) and 0.79 (95% CI: 0.46–1.35), respectively. A positive ultrasound result increases and negative ultrasound result decreases the probability that a nonpalpable testis is located within the abdomen from 55% to 64% and 49%, respectively. Significant heterogeneity limited the precision of these estimates, which was attributable to variability in the reporting of selection criteria, ultrasound methodology, and differences in the proportion of intraabdominal testes. CONCLUSIONS: Ultrasound does not reliably localize nonpalpable testes and does not rule out an intraabdominal testis. Eliminating the use of ultrasound will not change management of nonpalpable cryptorchidism but will decrease health care expenditures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1542/peds.2010-1800

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 169

Metadata

Authors
Tasian, G. E., & Copp, H. L.
Venue
Pediatrics
Published
2011-01-01
Volume
127
Issue
1
Pages
119-128
ISSN
  • 0031-4005 (ISSN-L)
  • 1098-4275
OpenAlex
W2148685809
Cited by
169
References
3
FWCI
1.81
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Performance of Ultrasound in Nonpalpable Cryptorchidism: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1542/peds.2010-1800
The paper
Tasian, G. E., & Copp, H. L. (2011). Diagnostic Performance of Ultrasound in Nonpalpable Cryptorchidism: A Systematic Review and Meta-analysis. Pediatrics. https://doi.org/10.1542/peds.2010-1800

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.