The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Diagnostic Performance of Ultrasound in Nonpalpable Cryptorchidism: A Systematic Review and Meta-analysis
Open accessAbstract
CONTEXT: Ultrasound is frequently obtained during the presurgical evaluation of boys with nonpalpable undescended testes, but its clinical utility is uncertain. OBJECTIVE: To determine the diagnostic performance of ultrasound in localizing nonpalpable testes in pediatric patients. METHODS: English-language articles were identified by searching Medline, Embase, and the Cochrane Library. We included studies of subjects younger than 18 years who had preoperative ultrasound evaluation for nonpalpable testes and whose testis position was determined by surgery. Data on testis location determined by ultrasound and surgery were extracted by 2 independent reviewers, from which ultrasound performance characteristics (true-positives, false-positives, false-negatives, and true-negatives) were derived. Meta-analysis of 12 studies (591 testes) was performed by using a random-effects regression model; composite estimates of sensitivity, specificity, and likelihood ratios were calculated. RESULTS: Ultrasound has a sensitivity of 45% (95% confidence interval [CI]: 29–61) and a specificity of 78% (95% CI: 43–94). The positive and negative likelihood ratios are 1.48 (95% CI: 0.54–4.03) and 0.79 (95% CI: 0.46–1.35), respectively. A positive ultrasound result increases and negative ultrasound result decreases the probability that a nonpalpable testis is located within the abdomen from 55% to 64% and 49%, respectively. Significant heterogeneity limited the precision of these estimates, which was attributable to variability in the reporting of selection criteria, ultrasound methodology, and differences in the proportion of intraabdominal testes. CONCLUSIONS: Ultrasound does not reliably localize nonpalpable testes and does not rule out an intraabdominal testis. Eliminating the use of ultrasound will not change management of nonpalpable cryptorchidism but will decrease health care expenditures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910
The Bagplot: A Bivariate Boxplot
Rousseeuw, P. J., Ruts, I., & Tukey, J. W. (1999) · The American Statistician · doi:10.2307/2686061 · Cited by 568
Cited by
Evaluation and Treatment of Cryptorchidism: AUA Guideline
Kolon, T. F., Herndon, C. D. A., Baker, L. A., Baskin, L. S., Baxter, C. G., Cheng, E. Y., Diaz, M., Lee, P. A., Seashore, C. J., Tasian, G. E., et al. (2014) · Journal of Urology · doi:10.1016/j.juro.2014.05.005 · Cited by 536
Self-citationUltrasound of the male genital tract in relation to male reproductive health
Lotti, F., & Maggi, M. (2015) · Human Reproduction Update · doi:10.1093/humupd/dmu042 · Cited by 365
Metadata
- Authors
- Tasian, G. E., & Copp, H. L.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2011-01-01
- Volume
- 127
- Issue
- 1
- Pages
- 119-128
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2148685809
- Cited by
- 169
- References
- 3
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic Performance of Ultrasound in Nonpalpable Cryptorchidism: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1542/peds.2010-1800
- The paper
- Tasian, G. E., & Copp, H. L. (2011). Diagnostic Performance of Ultrasound in Nonpalpable Cryptorchidism: A Systematic Review and Meta-analysis. Pediatrics. https://doi.org/10.1542/peds.2010-1800
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.