Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 257

The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.

Prognostic Tests in Term Neonates With Hypoxic-Ischemic Encephalopathy: A Systematic Review

van Laerhoven, Henriette, de Haan, Timo R., Offringa, Martin, Post, Bart, van der Lee, Johanna H.·2013·Pediatrics

Abstract

BACKGROUND AND OBJECTIVE: Hypoxic-ischemic encephalopathy (HIE) after perinatal asphyxia in term neonates causes long-term neurologic sequelae or death. A reliable evidence-based prognosis is essential. The study goal was to investigate the prognostic value of currently used clinical tests in neonatal patients with perinatal asphyxia and HIE. METHODS: Searches were made on MEDLINE, Embase, Central, and CINAHL for studies occurring between January 1980 and November 2011. Studies were included if they (1) evaluated outcome in term infants with perinatal asphyxia and HIE, (2) evaluated prognostic tests, and (3) reported outcome at a minimal follow-up age of 18 months. Study selection, assessment of methodologic quality, and data extraction were performed by 3 independent reviewers. Pooled sensitivities and specificities of investigated tests were calculated when possible. RESULTS: Of the 259 relevant studies, 29 were included describing 13 prognostic tests conducted 1631 times in 1306 term neonates. A considerable heterogeneity was noted in test performance, cut-off values, and outcome measures. The most promising tests were amplitude-integrated electroencephalography (sensitivity 0.93, [95% confidence interval 0.78–0.98]; specificity 0.90 [0.60–0.98]), EEG (sensitivity 0.92 [0.66–0.99]; specificity 0.83 [0.64–0.93]), and visual evoked potentials (sensitivity 0.90 [0.74–0.97]; specificity 0.92 [0.68–0.98]). In imaging, diffusion weighted MRI performed best on specificity (0.89 [0.62–0.98]) and T1/T2-weighted MRI performed best on sensitivity (0.98 [0.80–1.00]). Magnetic resonance spectroscopy demonstrated a sensitivity of 0.75 (0.26–0.96) with poor specificity (0.58 [0.23–0.87]). CONCLUSIONS: This evidence suggests an important role for amplitude-integrated electroencephalography, EEG, visual evoked potentials, and diffusion weighted and conventional MRI. Given the heterogeneity in the tests’ performance and outcomes studied, well-designed large prospective studies are needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1542/peds.2012-1297

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 45 references

Cited by

See all 257

Metadata

Authors
van Laerhoven, H., de Haan, T. R., Offringa, M., Post, B., & van der Lee, J. H.
Venue
Pediatrics
Published
2013-01-01
Volume
131
Issue
1
Pages
88-98
ISSN
  • 0031-4005 (ISSN-L)
  • 1098-4275
OpenAlex
W2165221888
Cited by
257
References
45
FWCI
2.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prognostic Tests in Term Neonates With Hypoxic-Ischemic Encephalopathy: A Systematic Review. https://app.cochat.ai/papers/10.1542/peds.2012-1297
The paper
van Laerhoven, H., de Haan, T. R., Offringa, M., Post, B., & van der Lee, J. H. (2013). Prognostic Tests in Term Neonates With Hypoxic-Ischemic Encephalopathy: A Systematic Review. Pediatrics. https://doi.org/10.1542/peds.2012-1297

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.