Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 273

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Neonatal Intubation Practice and Outcomes: An International Registry Study

Open access
Foglia, Elizabeth E., Ades, Anne, Sawyer, Taylor, Glass, Kristen M., Singh, Neetu, Jung, Philipp, Quek, Bin Huey, Johnston, Lindsay C., Barry, James, Zenge, Jeanne, Moussa, Ahmed, Kim, Jae H., DeMeo, Stephen D., Napolitano, Natalie, Nadkarni, Vinay, Nishisaki, Akira, for the NEAR4NEOS Investigators·2019·Pediatrics

Abstract

BACKGROUND AND OBJECTIVES: Neonatal tracheal intubation is a critical but potentially dangerous procedure. We sought to characterize intubation practice and outcomes in the NICU and delivery room (DR) settings and to identify potentially modifiable factors to improve neonatal intubation safety. METHODS: We developed the National Emergency Airway Registry for Neonates and collected standardized data for patients, providers, practices, and outcomes of neonatal intubation. Safety outcomes included adverse tracheal intubation–associated events (TIAEs) and severe oxygen desaturation (≥20% decline in oxygen saturation). We examined the relationship between intubation characteristics and adverse events with univariable tests and multivariable logistic regression. RESULTS: We captured 2009 NICU intubations and 598 DR intubations from 10 centers. Pediatric residents attempted 15% of NICU and 2% of DR intubations. In the NICU, the first attempt success rate was 49%, adverse TIAE rate was 18%, and severe desaturation rate was 48%. In the DR, 46% of intubations were successful on the first attempt, with 17% TIAE rate and 31% severe desaturation rate. Site-specific TIAE rates ranged from 9% to 50% (P < .001), and severe desaturation rates ranged from 29% to 69% (P = .001). Practices independently associated with reduced TIAEs in the NICU included video laryngoscope (adjusted odds ratio 0.46, 95% confidence interval 0.28–0.73) and paralytic premedication (adjusted odds ratio 0.38, 95% confidence interval 0.25–0.57). CONCLUSIONS: We implemented a novel multisite neonatal intubation registry and identified potentially modifiable factors associated with adverse events. Our results will inform future interventional studies to improve neonatal intubation safety.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1542/peds.2018-0902

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Metadata

Authors
Foglia, E. E., Ades, A., Sawyer, T., Glass, K. M., Singh, N., Jung, P., Quek, B. H., Johnston, L. C., Barry, J., Zenge, J., Moussa, A., Kim, J. H., DeMeo, S. D., Napolitano, N., Nadkarni, V., Nishisaki, A., & for the NEAR4NEOS Investigators
Venue
Pediatrics
Published
2019-01-01
Volume
143
Issue
1
ISSN
  • 0031-4005 (ISSN-L)
  • 1098-4275
OpenAlex
W2905579452
Cited by
273
References
10
FWCI
26.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Neonatal Intubation Practice and Outcomes: An International Registry Study. https://app.cochat.ai/papers/10.1542/peds.2018-0902
The paper
Foglia, E. E., Ades, A., Sawyer, T., Glass, K. M., Singh, N., Jung, P., Quek, B. H., Johnston, L. C., Barry, J., Zenge, J., Moussa, A., Kim, J. H., DeMeo, S. D., Napolitano, N., Nadkarni, V., Nishisaki, A., & for the NEAR4NEOS Investigators. (2019). Neonatal Intubation Practice and Outcomes: An International Registry Study. Pediatrics. https://doi.org/10.1542/peds.2018-0902

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.