Excessive Handling as a Cause of Hypoxemia
The DOI matches its Crossref record.
Abstract
Continuous transcutaneous oxygen (TcPo2) monitoring was used to study low-birth-weight infants (15 control, 15 experimental) during their stay in the intensive care nursery (ICN). Twenty hours of continuous recordings were made of heart rate, respiratory rate, and TcPo2 in the first five days after birth. Personnel caring for the control infants were blind to the TcPo2 measurements. Those caring for the experimental group were instructed in the operation of the TcPo2 monitor and used the device to modify the timing and extent of procedures to minimize "undesirable time" (TcPo2 < 40 or > 100 torr). Control group infants had an average of 40 min/20 hr in "undesirable time." When personnel used TcPo2 monitoring to modify care this "undesirable time" was reduced to 6 min/20 hr. This difference was statistically significant (P < .001). Infants in the control group were handled more frequently, and experienced more hypoxemia. Of the hypoxemic time suffered by the control infants 75% was associated with handling. Only 5% of the hypoxemia or hyperoxemia was detected by blood Pao2 analysis or conventional monitors. Intermittent arterial blood gas sampling is an inadequate method for monitoring arterial oxygenation in low-birth-weight infants since hypoxemia and hyperoxemia are often missed. Continuous TcPo2 monitoring improves care by diminishing "undesirable time."
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Walker, C.-D., Bath, K. G., Joels, M., Korosi, A., Larauche, M., Lucassen, P. J., Morris, M. J., Raineki, C., Roth, T. L., Sullivan, R. M., et al. (2017) · Stress · doi:10.1080/10253890.2017.1343296 · Cited by 404
Analgesia in newborns given oral glucose
Skogsdal, Y., Eriksson, M., & Schollin, J. (1997) · Acta Paediatrica · doi:10.1111/j.1651-2227.1997.tb08872.x · Cited by 199
“These include effects on cardiovascular function as well as changes in metabolism and intracranial pressure (1,2,7-10).”
BackgroundStructural and Neurobehavioral Delay in Postnatal Brain Development of Preterm Infants1
Hüppi, P. S., Schuknecht, B., Boesch, C., Bossi, E., Felblinger, J., Fusch, C., & Herschkowitz, N. (1996) · Pediatric Research · doi:10.1203/00006450-199605000-00026 · Cited by 194
Pressure Ulcers in Neonates and Children: An NPUAP White Paper
Baharestani, M. M., & Ratliff, C. R. (2007) · Advances in Skin & Wound Care · doi:10.1097/01.asw.0000266646.43159.99 · Cited by 175
“In adult populations, the standard of care is to reposition every 2 hours, but repositioning premature neonates at this frequency can result in agitation, apnea, bradycardia, emesis, airway obstruction, hypoxemia, tachycardia, and slower oxygenation recovery time.(45,47) In a randomized, prospective study, 72 prematur…”
BackgroundMassage stimulates growth in preterm infants: A replication
Scafidi, F. A., Field, T. M., Schanberg, S. M., Bauer, C. R., Tucci, K., Roberts, J., Morrow, C., & Kuhn, C. M. (1990) · Infant Behavior and Development · doi:10.1016/0163-6383(90)90029-8 · Cited by 174
Metadata
- Authors
- Long, J. C., Philip, A. G. S., & Lucey, J. F.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 1980-02-01
- Volume
- 65
- Issue
- 2
- Pages
- 203-207
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W1905941446
- Cited by
- 211
- References
- 0
- FWCI
- 9.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Excessive Handling as a Cause of Hypoxemia. https://app.cochat.ai/papers/10.1542/peds.65.2.203
- The paper
- Long, J. C., Philip, A. G. S., & Lucey, J. F. (1980). Excessive Handling as a Cause of Hypoxemia. Pediatrics. https://doi.org/10.1542/peds.65.2.203
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.