Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 190

The DOI matches its Crossref record.

Evaluation of An End-Tidal CO2 Detector During Pediatric Cardiopulmonary Resuscitation

Bhende, Mananda S., Thompson, Ann E. · 1995 · Pediatrics

Abstract

Objective. To determine the utility of a disposable colorimetric end-tidal CO2 detector during pediatric cardiopulmonary resuscitation (CPR) for (1) confirming endotracheal tube (ETT) position, and (2) assessing the relationship between end-tidal CO2 recorded by this method and outcome of pediatric CPR. Design/setting. Prospective observations during CPR in a university children's hospital. Participants. Forty children (28 male, 12 female) aged 1 week to 10 years (25 children aged ≤1 year, mean age 27.2 months, median 7 months), weighing 2.5 to 40 kg (31 children weighing ≤15 kg, mean 10.94 kg, median 7 kg) who underwent a total of 48 endotracheal intubations during CPR. Methods. After intubation, ETT position was verified by usual clinical methods including direct visualization. The device was attached between the ETT and ventilation bag, the patient was manually ventilated, and a first reading was obtained. Any color change from purple (Area A, end-tidal CO2 < 0.5%) to tan or yellow (Area B or C, end-tidal CO2 ≥ 0.5%) was considered to be positive for airway intubation. CPR was conducted as pen Pediatric Advanced Life Support guidelines. A second reading was obtained when the decision to discontinue CPR was made. Results. All nine esophageal tube positions were correctly identified by the detector. Thirty-three of 39 tracheal tube positions were correctly identified (P < .001). For verifying ETT position, the device had a sensitivity of 84.6%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 60%. Readings were obtained at the end of CPR in 25 patients. All 13 patients who regained spontaneous circulation and survived to ICU admission had a second reading in the C range, while none of the 12 patients with a second reading in the A or B range survived. Both the first and second end-tidal CO2 readings in the C range correlated significantly with short-term survival (P = .01 and P < .001, respectively). Two patients were eventually discharged from the hospital. Conclusions. During CPR a positive test confirms placement of the ETT within the airway, whereas a negative test indicates either esophageal intubation or airway intubation with poor or absent pulmonary blood flow and requires an alternate means of confirmation of tube position. The detector may be of prognostic value for return of spontaneous circulation and short-term survival.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1542/peds.95.3.395

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 190

Metadata

Authors
Bhende, M. S., & Thompson, A. E.
Venue
Pediatrics
Published
1995-03-01
Volume
95
Issue
3
Pages
395-399
ISSN
  • 0031-4005 (ISSN-L)
  • 1098-4275
OpenAlex
W2161426131
Cited by
190
References
0
FWCI
5.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of An End-Tidal CO2 Detector During Pediatric Cardiopulmonary Resuscitation. https://app.cochat.ai/papers/10.1542/peds.95.3.395
The paper
Bhende, M. S., & Thompson, A. E. (1995). Evaluation of An End-Tidal CO2 Detector During Pediatric Cardiopulmonary Resuscitation. Pediatrics. https://doi.org/10.1542/peds.95.3.395

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.