Preliminary Results and Conclusions From the PRESSS Five-Story Precast Concrete Test Building
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A large-scale five-story precast concrete building constructed to 60 percent scale was tested under simulated seismic loading as the culmination of the 10-year PRESSS (Precast Seismic Structural Systems) research program. The building comprised four different ductile structural frame systems in one direction of response and a jointed structural wall system in the orthogonal direction. The test structure was subjected to seismic input levels equivalent to at least 50 percent higher than those required for UBC (Uniform Building Code) Seismic Zone 4. The behavior of the structure was extremely satisfactory, with only minimal damage in the shear wall direction, and no significant strength loss in the frame direction, despite being taken to drift levels up to 4.5 percent, more than 100 percent higher than the design drift level. The test validated the Displacement-Based Design (DBD) approach used to determine the required strength and confirmed the low damage and low residual drift expected of the building.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reinforced Concrete Response to Simulated Earthquakes
Takeda, T., Sözen, M. A., & Nielsen, N. N. (1970) · Journal of the Structural Division · doi:10.1061/jsdeag.0002765 · Cited by 1,591
An Overview of the PRESSS Five-Story Precast Test Building
Nakaki, S. D., Stanton, J. F., & Sritharan, S. (1999) · PCI Journal · doi:10.15554/pcij.03011999.26.39 · Cited by 204
Self-citationThe PRESSS Program Current Status and Proposed Plans for Phase III
Priestley, M. J. N. (1996) · PCI Journal · doi:10.15554/pcij.03011996.22.40 · Cited by 197
Self-citation
Cited by
Posttensioned Energy Dissipating Connections for Moment-Resisting Steel Frames
Christopoulos, C., Filiatrault, A., Uang, C.-M., & Folz, B. (2002) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2002)128:9(1111 · Cited by 538
Marriott, D., Pampanin, S., & Palermo, A. (2009) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.857 · Cited by 383
Marriott, D., Pampanin, S., Bull, D., & Palermo, A. (2008) · Bulletin of the New Zealand Society for Earthquake Engineering · doi:10.5459/bnzsee.41.2.90-103 · Cited by 187
“As part of Phase III of the United States PRESSS program (PREcast Seismic Structural Systems (Priestley et al. 1999)), a 60% scale prototype building was constructed and tested (Pseudo-dynamic testing) comprising of a precast posttensioned coupled wall system orthogonal to a hybrid moment resisting…”
BackgroundMethodSelf‐centering structural systems with combination of hysteretic and viscous energy dissipations
Kam, W. Y., Pampanin, S., Palermo, A., & Carr, A. J. (2010) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.983 · Cited by 178
“Structural damage and residual deformations (therefore repair cost) are minimized to negligible levels through the rocking mechanism and self-centering capabilities without any significant increase to peak responses, as shown in pseudo-dynamic testing [4, 5, 10] and numerical analyses [6, 11–13].”
BackgroundExperimental Investigation of Self-Centering Cross-Laminated Timber Walls
Ganey, R., Berman, J., Akbas, T., Loftus, S., Daniel Dolan, J., Sause, R., Ricles, J., Pei, S., Lindt, J. V. D., & Blomgren, H.-E. (2017) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001877 · Cited by 176
Metadata
- Authors
- Priestley, M. J. N., Sritharan, S. (., Conley, J. R., & Stefano Pampanin, S.
- Venue
- PCI Journal
- Published
- 1999-11-01
- Volume
- 44
- Issue
- 6
- Pages
- 42-67
- ISSN
- 0887-9672 (ISSN-L)
- OpenAlex
- W1995692653
- Cited by
- 873
- References
- 3
- FWCI
- 28.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.