Cited by 150Magnesium Alloys: Properties and ApplicationsTitanium Alloys Microstructure and PropertiesMagnesium in Health and Disease

Magnesium-based biodegradable alloys: Degradation, application, and alloying elements

Open access
Pogorielov, Maksym, Husak, Eugenia, Solodivnik, Alexandr, Zhdanov, Sergii·2017·Interventional Medicine and Applied Science

Abstract

In recent years, the paradigm about the metal with improved corrosion resistance for application in surgery and orthopedy was broken. The new class of biodegradable metal emerges as an alternative for biomedical implants. These metals corrode gradually with an appropriate host response and release of corrosion products. And it is absolutely necessary to use essential metals metabolized by hosting organism with local and general nontoxic effect. Magnesium serves this aim best; it plays the essential role in body metabolism and should be completely excreted within a few days after degradation. This review summarizes data from Mg discovery and its first experimental and clinical application of modern concept of Mg alloy development. We focused on biodegradable metal application in general surgery and orthopedic practice and showed the advantages and disadvantages Mg alloys offer. We focused on methods of in vitro and in vivo investigation of degradable Mg alloys and correlation between these methods. Based on the observed data, a better way for new alloy pre-clinical investigation is suggested. This review analyzes possible alloying elements that improve corrosion rate, mechanical properties, and gives the appropriate host response.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1556/1646.9.2017.1.04

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The clinical application of magnesium is limited due to the difficulty in controlling the timing of degradation in physiological environments.

    “However, the clinical application of magnesium is limited due to its rapid corrosion and the consequent rapid deterioration of mechanical properties, as well as the difficulty in controlling the timing of degradation in physiological environments [33,35].”
  • The clinical application of magnesium is limited due to its rapid corrosion and the consequent rapid deterioration of mechanical properties.

    “However, the clinical application of magnesium is limited due to its rapid corrosion and the consequent rapid deterioration of mechanical properties, as well as the difficulty in controlling the timing of degradation in physiological environments [33,35].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 51

  1. [1]Fagali NS Grilloa CA Puntarulo S Fernández Lorenzo de Mele MA: Cytotoxicity of corrosion products of degradable Fe-based stents: Relevance of pH and insoluble products. Colloids Surf B Biointerfaces 128, 480– 488 (2015) 25797480
  2. [2]Moravej M Mantovani D: Biodegradable metals for cardiovascular stent application: Interests and new opportunities. Int J Mol Sci 12, 4250– 4270 (2011) 21845076 PMC3155349
  3. [3]Mani G Feldman MD Patel D Agrawal CM: Coronary stents: A materials perspective. Biomaterials 28, 1689– 1710 (2007) 17188349
  4. [4]Peuster M Wohlsein P Brugmann M Ehlerding M Seidler K Fink C Brauer H Fischer A Hausdorf G: A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal – Results 6–18 months after implantation into New Zealand white rabbits. Heart 86, 563– 569 (2001) 11602554 PMC1729971
  5. [5]Purnama A Hermawan H Couet J Mantovani D: Assessing the biocompatibility of degradable metallic materials: State-of-the-art and focus on the potential of genetic regulation. Acta Biomater 6, 1800– 1807 (2010) 20176149
  6. [6]Kubásek J Vojtěch D Jablonská E Pospíšilová I Lipov J Ruml T: Structure, mechanical characteristics and in vitro degradation, cytotoxicity, genotoxicity and mutagenicity of novel biodegradable Zn–Mg alloys. Mater Sci Eng C Mater Biol Appl 58, 24– 35 (2016) 26478283
  7. [7]Murni NS Dambatta MS Yeap SK Froemming GR Hermawan H: Cytotoxicity evaluation of biodegradable Zn-3Mg alloy toward normal human osteoblast cells. Mater Sci Eng C 49, 560– 566 (2015) 25686984
  8. [8]Sanchez AH Luthringer BJ Feyerabend F Willumeit R: Mg and Mg alloys: How comparable are in vitro and in vivo corrosion rates? A review. Acta Biomater 13, 16– 31 (2015) 25484334
  9. [11]Zeng RC Zhang J Huang WJ Dietzel W Kainer KU Blawert C Wei KE: Review of studies on corrosion of magnesium alloys. Trans Nonferr Metal Soc China 16, 763– 771 (2006)
  10. [12]Witte F: Reprint of: The history of biodegradable magnesium implants: A review. Acta Biomater 23, 28– 40 (2015) 26235343
  11. [15]Hofstetter J Martinelli E Pogatscher S Schmutz P Povoden-Karadeniz E Weinberg AM Uggowitzer PJ Löffler JF: Influence of trace impurities on the in vitro and in vivo degradation of biodegradable Mg–5Zn–0.3Ca alloys. Acta Biomater 23, 347– 353 (2015) 25983315
  12. [29]Stone P Lord JW Jr: An experimental study of the thrombogenic properties of magnesium and magnesium–aluminum wire in the dog’s aorta. Surgery 30, 987– 993 (1951) 14901224
  13. [30]Nagels J Stokdijk M Rozing PM: Stress shielding and bone resorption shoulder arthroplasty. J Shoulder Elbow Surg 12, 35– 39 (2003) 12610484
  14. [31]Wang ML Nesti LJ Tuli R Lazatin J Danielson KG Sharkey PF Tuan RS: Titanium particles suppress expression of osteoblastic phenotype in human mesenchymal stem cells. J Orthop Res 20, 1175– 1184 (2002) 12472226
  15. [32]Park JB Kim YK (2003): Metallic biomaterials. In: Biomaterials: Principles and Application, eds Park JB Bronzino JD, CRC Press, Boca Raton, pp. 1– 20
  16. [34]Saris NE Mervaala E Karppanen H Khawaja JA Lewenstam A: Magnesium: An update on physiological, clinical and analytical aspects. Clin Chim Acta 294, 1– 26 (2000) 10727669
  17. [36]Yamasaki Y Yoshida Y Okazaki M Shimazu A Uchida T Kubo T Akagawa Y Hamada Y Takahashi J Matsuura N: Synthesis of functionally graded MgCO3 apatite accelerating osteoblast adhesion. J Biomed Mater Res A 62, 99– 105 (2002) 12124791
  18. [37]Zreiqat H Howlett CR Zannettino A Evans P Schulze-Tanzil G Knabe C Shakibaei M: Mechanisms of magnesium-stimulated adhesion of osteoblastic cells to commonly used orthopaedic implants. J Biomed Mater Res 62, 175– 184 (2002) 12209937
  19. [49]Witte F Kaese V Haferkamp H Switzer E Meyer-Lindenberg C Wirth CJ Windhagen H: In vivo corrosion of four magnesium alloys and the associated bone response. Biomaterials 26, 3557– 3563 (2005) 15621246
  20. [51]Wang J Jiang H Bi Y Sun J Chen M Liu D: Effects of gas produced by degradation of Mg–Zn–Zr Alloy on cancellous bone tissue. Mater Sci Eng C Mater Biol Appl 55, 556– 561 (2015) 26117789
  21. [54]Liu Y Bian D Wu Y Li N Qiu K Zheng Y Han Y: Influence of biocompatible metal ions (Ag, Fe, Y) on the surface chemistry, corrosion behavior and cytocompatibility of Mg–1Ca alloy treated with MEVVA. Colloids Surf B Biointerfaces 133, 99– 107 (2015) 26094143
  22. [55]Han J Wan P Ge Y Fan X Tan L Li J Yang K: Tailoring the degradation and biological response of a magnesium–strontium alloy for potential bone substitute application. Mater Sci Eng C 58, 799– 811 (2016) 26478374
  23. [56]Zhou YL Li Y Luo DM Ding Y Hodgson P: Microstructures, mechanical and corrosion properties and biocompatibility of as extruded Mg–Mn–Zn–Nd alloys for biomedical applications. Mater Sci Eng C Mater Biol Appl 49, 93– 100 (2015) 25686931
  24. [58]Zhen Z Xi T-F Zheng Y-F: A review on in vitro corrosion performance test of biodegradable metallic materials. Trans Nonferr Metal Soc China 23, 2283– 2293 (2013)
  25. [59]Zhang S Zhang X Zhao C Li J Song Y Xie C Tao H Zhang Y He Y Jiang Y Bian Y: Research on an Mg–Zn alloy as a degradable biomaterial. Acta Biomater 6, 626– 640 (2010) 19545650
  26. [63]Walker J Shadanbaz S Kirkland NT Stace E Woodfield T Staiger MP Diaz GJ: Magnesium alloys: Predicting in vivo corrosion with in vitro immersion testing. J Biomed Mater Res B Appl Biomater 100, 1134– 1141 (2012) 22331609
  27. [64]Gu X Zheng Y Cheng Y Zhong S Xi T: In vitro corrosion and biocompatibility of binary magnesium alloys. Biomaterials 30, 484– 498 (2009) 19000636
  28. [66]Wang H Shi Z: In vitro biodegradation behavior of magnesium and magnesium alloy. J Biomed Mater Res B Appl Biomater 98, 203– 209 (2011) 21732527
  29. [68]Kirkland NT Birbilis N Staiger MP: Assessing the corrosion of biodegradable magnesium implants: A critical review of current methodologies and their limitations. Acta Mater 8, 925– 936 (2012) 22134164
  30. [69]Muller WD de Mele MF Nascimento ML Zeddies M: Degradation of magnesium and its alloys: Dependence on the composition of the synthetic biological media. J Biomed Mater Res A 90, 487– 495 (2009) 18563809
  31. [73]Yang W Zhang Y Yang J Tan L Yang K: Potential antiosteoporosis effect of biodegradable magnesium implanted in STZ-induced diabetic rats. J Biomed Mater Res A 99, 386– 394 (2011) 22021186
  32. [74]Chai H Guo L Wang X Gao X Liu K Fu Y Guan J Tan L Yang K: In vitro and in vivo evaluations on osteogenesis and biodegradability of a beta-tricalcium phosphate coated magnesium alloy. J Biomed Mater Res A 100, 293– 304 (2011) 22045631
  33. [75]Kraus T Fischerauer SF Hanzi AC Uggowitzer PJ Loffler JF Weinberg AM: Magnesium alloys for temporary implants in osteosynthesis: In vivo studies of their degradation and interaction with bone. Acta Biomater 8, 1230– 1238 (2012) 22107870
  34. [77]Witte F Fischer J Nellesen J Crostack HA Kaese V Pisch A Beckmann F Windhagen H: In vitro and in vivo corrosion measurements of magnesium alloys. Biomaterials 27, 1013– 1018 (2006) 16122786
  35. [78]Erdmann N Bondarenko A Hewicker-Trautwein M Angrisani N Reifenrath J Lucas A Meyer-Lindenberg A: Evaluation of the soft tissue biocompatibility of MgCa0.8 and surgical steel 316L in vivo: A comparative study in rabbits. Biomed Eng Online 9, 63 (2010) 20974008 PMC2976742
  36. [80]Witte F Ulrich H Rudert M Willbold E: Biodegradable magnesium scaffolds: Part 1: Appropriate inflammatory response. J Biomed Mater Res A 81, 748– 756 (2007) 17390368
  37. [81]Xu LP Yu GN Zhang E Pan F Yang K: In vivo corrosion behavior of Mg–Mn–Zn alloy for bone implant: Application. J Biomed Mater Res A 83, 703– 711 (2007) 17549695
  38. [85]Friedrich HE Mordike BL (2006): Magnesium Technology. Springer-Verlag, Berlin – Heidelberg
  39. [88]Ferreira PC Piai Kde A Takayanagui AM Segura-Munoz SI: Aluminum as a risk factor for Alzheimer’s disease. Rev Lat Am Enfermagem 16, 151– 157 (2008) 18392545
  40. [89]Okazaki Y Rao S Ito Y Tateishi T: Corrosion resistance, mechanical properties, corrosion fatigue strength and cytocompatibility of new Ti alloys without Al and V. Biomaterials 19, 1197– 1215 (1998) 9720903
  41. [90]Shingde M Hughes J Boadle R Wills EJ Pamphlett R: Macrophagic myofasciitis associated with vaccine-derived aluminium. Med J Aust 183, 145– 146 (2005) 16053418
  42. [91]Lastra MD Pastelin R Camacho A Monroy B Aguilar AE: Zinc intervention on macrophages and lymphocytes response. J Trace Elem Med Biol 15, 5– 10 (2001) 11603828
  43. [92]Saltman PD Strause LG: The role of trace minerals in osteoporosis. J Am Coll Nutr 12, 384– 389 (1993) 8409100
  44. [93]Bowen PK Drelich J Goldman J: Zinc exhibits ideal physiological corrosion behavior for bioabsorbable stents. Adv Mater 25, 2577– 2582 (2013) 23495090
  45. [94]Zhang B Wang Y Geng L (2011): Research on Mg-Zn-Ca alloy as degradable biomaterial. In: Biomaterials – Physics and Chemistry, ed Pignatello R, InTech, Rijeka, pp. 183– 204
  46. [95]Bruno Z Peter JU Jörg FL: MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants. Nat Mater 8, 887– 891 (2009) 19783982
  47. [98]Huan Z Leeflang M Zhou J Fratila-Apachitei L Duszczyk J: In vitro degradation behavior and cytocompatibility of Mg–Zn–Zr alloys. J Mater Sci Mater Med 21, 2623– 2635 (2010) 20532960 PMC2935537
  48. [103]Kirkland NT Birbilis N Walker J Woodfield T Dias GJ Staiger MP: In vitro dissolution of magnesium–calcium binary alloys: Clarifying the unique role of calcium additions in bioresorbable magnesium implant alloys. Biomed Mater Res B Appl Biomater 95, 91– 100 (2010) 20725953
  49. [104]Aschner M Guilarte TR Schneider JS Zheng W: Manganese: Recent advances in understanding its transport and neurotoxicity. Toxicol Appl Pharmacol 221, 131– 147 (2007) 17466353 PMC1950780
  50. [105]Friedrich HE Mordike BL (2005): Magnesium Technology – Metallurgy, Design Date, Applications. Springer-Verlag, Berlin – Heidelberg – New York
  51. [108]Li Y Wen C Mushahary D Sravanthi R Harishankar N Pande G Hodgson P: Mg–Zr–Sr alloys as biodegradable implant materials. Acta Biomater 8, 3177– 3188 (2012) 22531570

Cited by

Sorted by citations

Authors
Pogorielov, M., Husak, E., Solodivnik, A., & Zhdanov, S.
Affiliations
Sumy State University (UA)
Corresponding author
Pogorielov, Maksym
Venue
Interventional Medicine and Applied Science
Published
2017-03
Volume
9
Issue
1
Pages
27-38
ISSN
  • 2061-1617 (ISSN-L)
  • 2061-5094
OpenAlex
W2599112746
Cited by
150
References
1
Citations by year
2026: 16 · 2025: 15 · 2024: 20 · 2023: 11 · 2022: 16 · 2021: 26 · 2020: 17 · 2019: 12 · 2018: 15 · 2017: 2
FWCI
0.91
Type
journal article
Language
en
Open access
Locations
  • Interventional Medicine and Applied Science (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Biomaterials › Magnesium Alloys: Properties and Applications
  • Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
  • Health Sciences › Nursing › Nutrition and Dietetics › Magnesium in Health and Disease
Keywords
magnesium alloys, biodegradable metals, biodegradable implants, corrosion behavior, alloying elements, corrosion products, host response, orthopedic implants, surgical implants, mechanical properties, preclinical evaluation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review