CoChat

Analysis of tributyltin and triphenyltin in water by ionic liquid-headspace single-drop microextraction then HPLC with fluorimetric detection

Open access
Sheikhloie, H., Saber-Tehrani, M., Abrumand-Azar, P., Waqif-Husain, S. · 2009 · Acta Chromatographica
Cited by 21

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

A novel method using ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6] as extracting solvent in head-space single drop microextraction followed by HPLC with fluorimetric detection has been developed for analysis of tributyltin (TBT) and triphenyltin (TPhT) in water. Experimental conditions related to SDME performance, for example micro-drop volume, extraction time, stirring rate, salt content, and sample volume were investigated. Under the optimized conditions (micro-drop volume, 10 μL; extraction time, 30 min; stirring rate, 900 rpm; salt concentration, 6% sample volume, 6 mL), the linear range, detection limit (S/N = 3), and reproducibility (RSD, n = 4) were 1−100 μL−1, 0.62 μL−1, and 7.8%, respectively, for TBT, and 2−100 μL−1, 0.95 μL−1, and 8.3% for TPhT. All micro-extraction experiments were performed at room temperature (25 ± 1°C). The optimized procedure was successfully used for analysis of TBT and TPhT in deionized water and waste water. Recovery of a 25 μL−1 spike was in the range 86.9–92.1%. The method has also been used for analysis of TBT and TPhT in natural water.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1556/achrom.21.2009.4.5

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 21

Metadata

Authors
Sheikhloie, H., Saber-Tehrani, M., Abrumand-Azar, P., & Waqif-Husain, S.
Venue
Acta Chromatographica
Published
2009-12
Volume
21
Issue
4
Pages
577-589
ISSN
  • 1233-2356 (ISSN-L)
  • 2083-5736
OpenAlex
W2013836933
Cited by
21
References
2
FWCI
2.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.