The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
TEM Sample Preparation and FIB-Induced Damage
Abstract
One of the most important applications of a focused ion beam (FIB) workstation is preparing samples for transmission electron microscope (TEM) investigation. Samples must be uniformly thin to enable the analyzing beam of electrons to penetrate. The FIB enables not only the preparation of large, uniformly thick, sitespecific samples, but also the fabrication of lamellae used for TEM samples from composite samples consisting of inorganic and organic materials with very different properties. This article gives an overview of the variety of techniques that have been developed to prepare the final TEM specimen. The strengths of these methods as well as the problems, such as FIB-induced damage and Ga contamination, are illustrated with examples. Most recently, FIB-thinned lamellae were used to improve the spatial resolution of electron backscatter diffraction and energy-dispersive x-ray mapping. Examples are presented to illustrate the capabilities, difficulties, and future potential of FIB.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of focused ion beam milling techniques for TEM specimen preparation
Giannuzzi, L. A., & Stevie, F. A. (1999) · Micron · doi:10.1016/s0968-4328(99)00005-0 · Cited by 1,210
Self-citationIntroduction to Focused Ion Beams: Instrumentation, Theory, Techniques and Practice
(2005) · Springer eBooks · doi:10.1007/b101190 · Cited by 830
Reducing focused ion beam damage to transmission electron microscopy samples
Kato, N. I. (2004) · Journal of Electron Microscopy · doi:10.1093/jmicro/dfh080 · Cited by 226
Effects of diffusion induced recrystallization on volume diffusion in the copper-nickel system
Schwarz, S. M., Kempshall, B. W., & Giannuzzi, L. A. (2003) · Acta Materialia · doi:10.1016/s1359-6454(03)00082-x · Cited by 66
Self-citationYaguchi, T., Kamino, T., Ishitani, T., & Urao, R. (1999) · Microscopy and Microanalysis · doi:10.1017/s1431927699000203 · Cited by 34
Self-citation
Cited by
Gas-assisted focused electron beam and ion beam processing and fabrication
Utke, I., Hoffmann, P., & Melngailis, J. (2008) · Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena · doi:10.1116/1.2955728 · Cited by 1,026
Yan, P., Zheng, J., Gu, M., Xiao, J., Zhang, J.-G., & Wang, C.-M. (2017) · Nature Communications · doi:10.1038/ncomms14101 · Cited by 1,010
Zhu, T., & Li, J. (2010) · Progress in Materials Science · doi:10.1016/j.pmatsci.2010.04.001 · Cited by 828
Primary radiation damage: A review of current understanding and models
Nordlund, K., Zinkle, S. J., Sand, A. E., Granberg, F., Averback, R. S., Stoller, R. E., Suzudo, T., Malerba, L., Banhart, F., Weber, W. J., et al. (2018) · Journal of Nuclear Materials · doi:10.1016/j.jnucmat.2018.10.027 · Cited by 681
Fractal-like hierarchical organization of bone begins at the nanoscale
Reznikov, N., Bilton, M., Lari, L., Stevens, M. M., & Kröger, R. (2018) · Science · doi:10.1126/science.aao2189 · Cited by 661
Metadata
- Authors
- Mayer, J., Giannuzzi, L. A., Kamino, T., & Michael, J.
- Venue
- MRS Bulletin
- Published
- 2007-05
- Volume
- 32
- Issue
- 5
- Pages
- 400-407
- ISSN
- 0883-7694 (ISSN-L)
- 1938-1425
- OpenAlex
- W2166060383
- Cited by
- 896
- References
- 5
- FWCI
- 18.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.