The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cantilever Sensors: Nanomechanical Tools for Diagnostics
Open accessAbstract
Cantilever sensors have attracted considerable attention over the last decade because of their potential as a highly sensitive sensor platform for high throughput and multiplexed detection of proteins and nucleic acids. A micromachined cantilever platform integrates nanoscale science and microfabrication technology for the label-free detection of biological molecules, allowing miniaturization. Molecular adsorption, when restricted to a single side of a deformable cantilever beam, results in measurable bending of the cantilever. This nanoscale deflection is caused by a variation in the cantilever surface stress due to biomolecular interactions and can be measured by optical or electrical means, thereby reporting on the presence of biomolecules. Biological specificity in detection is typically achieved by immobilizing selective receptors or probe molecules on one side of the cantilever using surface functionalization processes. When target molecules are injected into the fluid bathing the cantilever, the cantilever bends as a function of the number of molecules bound to the probe molecules on its surface. Mass-produced, miniature silicon and silicon nitride microcantilever arrays offer a clear path to the development of miniature sensors with unprecedented sensitivity for biodetection applications, such as toxin detection, DNA hybridization, and selective detection of pathogens through immunological techniques. This article discusses applications of cantilever sensors in cancer diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weighing of biomolecules, single cells and single nanoparticles in fluid
Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R. (2007) · Nature · doi:10.1038/nature05741 · Cited by 1,213
Self-citation
Cited by
Eom, K., Park, H. S., Yoon, D. S., & Kwon, T. (2011) · Physics Reports · doi:10.1016/j.physrep.2011.03.002 · Cited by 464
Electrical biosensors and the label free detection of protein disease biomarkers
Luo, X., & Davis, J. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60077g · Cited by 460
Biosensors based on nanomechanical systems
Tamayo, J., Kosaka, P. M., Ruz, J. J., San Paulo, Á., & Calleja, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35293a · Cited by 391
Label-free biological and chemical sensors
Hunt, H. K., & Armani, A. M. (2010) · Nanoscale · doi:10.1039/c0nr00201a · Cited by 371
Biosensing using dynamic-mode cantilever sensors: A review
Johnson, B. N., & Mutharasan, R. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.054 · Cited by 314
Metadata
- Authors
- Datar, R., Kim, S., Jeon, S., Hesketh, P., Manalis, S., Boisen, A., & Thundat, T.
- Venue
- MRS Bulletin
- Published
- 2009-06
- Volume
- 34
- Issue
- 6
- Pages
- 449-454
- ISSN
- 0883-7694 (ISSN-L)
- 1938-1425
- OpenAlex
- W2084070785
- Cited by
- 163
- References
- 1
- FWCI
- 11.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.