Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 207

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Piezoresponse Force Microscopy: A Window into Electromechanical Behavior at the Nanoscale

Bonnell, D.A., Kalinin, S.V., Kholkin, A.L., Gruverman, A.·2009·MRS Bulletin

Abstract

Piezoresponse force microscopy (PFM) is a powerful method widely used for nanoscale studies of the electromechanical coupling effect in various materials systems. Here, we review recent progress in this field that demonstrates great potential of PFM for the investigation of static and dynamic properties of ferroelectric domains, nanofabrication and lithography, local functional control, and structural imaging in a variety of inorganic and organic materials, including piezoelectrics, semiconductors, polymers, biomolecules, and biological systems. Future pathways for PFM application in high-density data storage, nanofabrication, and spectroscopy are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1557/mrs2009.176

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 207

Metadata

Authors
Bonnell, D. A., Kalinin, S. V., Kholkin, A. L., & Gruverman, A.
Venue
MRS Bulletin
Published
2009-09
Volume
34
Issue
9
Pages
648-657
ISSN
  • 0883-7694 (ISSN-L)
  • 1938-1425
OpenAlex
W2170556853
Cited by
207
References
1
FWCI
7.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Piezoresponse Force Microscopy: A Window into Electromechanical Behavior at the Nanoscale. https://app.cochat.ai/papers/10.1557/mrs2009.176
The paper
Bonnell, D. A., Kalinin, S. V., Kholkin, A. L., & Gruverman, A. (2009). Piezoresponse Force Microscopy: A Window into Electromechanical Behavior at the Nanoscale. MRS Bulletin. https://doi.org/10.1557/mrs2009.176

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.