Evaluation of Abbott BinaxNOW Rapid Antigen Test for SARS-CoV-2 Infection at Two Community-Based Testing Sites — Pima County, Arizona, November 3–17, 2020
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Rapid antigen tests, such as the Abbott BinaxNOW COVID-19 Ag Card (BinaxNOW), offer results more rapidly (approximately 15-30 minutes) and at a lower cost than do highly sensitive nucleic acid amplification tests (NAATs) (1). Rapid antigen tests have received Food and Drug Administration (FDA) Emergency Use Authorization (EUA) for use in symptomatic persons (2), but data are lacking on test performance in asymptomatic persons to inform expanded screening testing to rapidly identify and isolate infected persons (3). To evaluate the performance of the BinaxNOW rapid antigen test, it was used along with real-time reverse transcription-polymerase chain reaction (RT-PCR) testing to analyze 3,419 paired specimens collected from persons aged ≥10 years at two community testing sites in Pima County, Arizona, during November 3-17, 2020. Viral culture was performed on 274 of 303 residual real-time RT-PCR specimens with positive results by either test (29 were not available for culture). Compared with real-time RT-PCR testing, the BinaxNOW antigen test had a sensitivity of 64.2% for specimens from symptomatic persons and 35.8% for specimens from asymptomatic persons, with near 100% specificity in specimens from both groups. Virus was cultured from 96 of 274 (35.0%) specimens, including 85 (57.8%) of 147 with concordant antigen and real-time RT-PCR positive results, 11 (8.9%) of 124 with false-negative antigen test results, and none of three with false-positive antigen test results. Among specimens positive for viral culture, sensitivity was 92.6% for symptomatic and 78.6% for asymptomatic individuals. When the pretest probability for receiving positive test results for SARS-CoV-2 is elevated (e.g., in symptomatic persons or in persons with a known COVID-19 exposure), a negative antigen test result should be confirmed by NAAT (1). Despite a lower sensitivity to detect infection, rapid antigen tests can be an important tool for screening because of their quick turnaround time, lower costs and resource needs, high specificity, and high positive predictive value (PPV) in settings of high pretest probability. The faster turnaround time of the antigen test can help limit transmission by more rapidly identifying infectious persons for isolation, particularly when used as a component of serial testing strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lu, X., Wang, L., Sakthivel, S. K., Whitaker, B., Murray, J., Kamili, S., Lynch, B., Malapati, L., Burke, S. A., Harcourt, J., et al. (2020) · Emerging Infectious Diseases · doi:10.3201/eid2608.201246 · Cited by 676 · cited 1×
“NP swabs were stored in phosphate buffered saline at 39°F (4°C) and analyzed within 24–48 hours by real-time RT-PCR using either the CDC 2019-nCoV Real-Time RT-PCR Diagnostic Panel for detection of SARS-CoV-2 (5) (2,582 swabs) or the Fosun COVID-19 RT-PCR Detection Kit (6) (837 swabs).”
MethodSelf-citationThe implications of silent transmission for the control of COVID-19 outbreaks
Moghadas, S. M., Fitzpatrick, M. C., Sah, P., Pandey, A., Shoukat, A., Singer, B. H., & Galvani, A. P. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2008373117 · Cited by 449 · cited 1×
“Because estimates suggest that over 50% of transmission occurs from persons who are presymptomatic or asymptomatic (9), expanded screening testing, potentially in serial fashion for reducing transmission in specific venues (e.”
BackgroundPaltiel, A. D., Zheng, A., & Walensky, R. P. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2020.16818 · Cited by 445 · cited 1×
“, in kindergarten through grade 12 schools, institutions of higher education, or congregate housing settings), which might improve test sensitivity in decting infection (10).”
BackgroundPilarowski, G. O. W., Marquez, C., Rubio, L., Peng, J., Martinez, J., Black, D., Chamie, G., Jones, D., Jacobo, J., Tulier-Laiwa, V., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa1890 · Cited by 86 · cited 2×
“The results of the current evaluation differ from those of an evaluation of the BinaxNOW antigen test in a community screening setting in San Francisco (7), which found a BinaxNOW antigen test overall sensitivity of 89.”
ResultInfluentialPinninti, S. G., Trieu, C., Pati, S. K., Latting, M., Cooper, J., Seleme, M. C., Boppana, S., Arora, N., Britt, W. J., & Boppana, S. B. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa882 · Cited by 51 · cited 1×
“First, anterior nasal swabs were used for BinaxNOW antigen testing, but NP swabs were used for real-time RT-PCR testing, which might have contributed to increased detection for the real-time RT-PCR assay (8).”
Method
Cited by
Brümmer, L. E., Katzenschlager, S., Gaeddert, M., Erdmann, C., Schmitz, S., Bota, M., Grilli, M., Larmann, J., Weigand, M. A., Pollock, N. R., et al. (2021) · PLOS Medicine · doi:10.1371/journal.pmed.1003735 · Cited by 298
Kang, T., Lu, J., Yu, T., Long, Y., & Liu, G. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114109 · Cited by 227
The impact of population-wide rapid antigen testing on SARS-CoV-2 prevalence in Slovakia
Pavelka, M., Van-Zandvoort, K., Abbott, S., Sherratt, K., Majdan, M., CMMID COVID-19 working group, Analýz, I. Z., Jarčuška, P., Krajčí, M., Flasche, S., et al. (2021) · Science · doi:10.1126/science.abf9648 · Cited by 205
COVID-19 Point-of-Care Diagnostics: Present and Future
Valera, E., Jankelow, A., Lim, J., Kindratenko, V., Ganguli, A., White, K., Kumar, J., & Bashir, R. (2021) · ACS Nano · doi:10.1021/acsnano.1c02981 · Cited by 181
Kost, G. J. (2021) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2020-0716-sa · Cited by 23
The Coronavirus Disease 2019 Spatial Care Path: Home, Community, and Emergency Diagnostic Portals
Kost, G. J. (2022) · Diagnostics · doi:10.3390/diagnostics12051216 · Cited by 13
Metadata
- Authors
- Prince-Guerra, J. L., Almendares, O., Nolen, L. D., Gunn, J. K. L., Dale, A. P., Buono, S. A., Deutsch-Feldman, M., Suppiah, S., Hao, L., Zeng, Y., Stevens, V. A., Knipe, K., Pompey, J., Atherstone, C., Bui, D. P., Powell, T., Tamin, A., Harcourt, J. L., Shewmaker, P. L., Medrzycki, M., Wong, P., Jain, S., Tejada-Strop, A., Rogers, S., Emery, B., Wang, H., Petway, M., Bohannon, C., Folster, J. M., MacNeil, A., Salerno, R., Kuhnert-Tallman, W., Tate, J. E., Thornburg, N. J., Kirking, H. L., Sheiban, K., Kudrna, J., Cullen, T., Komatsu, K. K., Villanueva, J. M., Rose, D. A., Neatherlin, J. C., Anderson, M., Rota, P. A., Honein, M. A., & Bower, W. A.
- Venue
- MMWR. Morbidity and Mortality Weekly Report
- Published
- 2021-01-22
- Volume
- 70
- Issue
- 3
- Pages
- 100-105
- ISSN
- 0149-2195 (ISSN-L)
- 1545-861X
- OpenAlex
- W3122288719
- Cited by
- 214
- References
- 5
- FWCI
- 15.03
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.