Rapid Analysis of Drugs: A Pilot Surveillance System To Detect Changes in the Illicit Drug Supply To Guide Timely Harm Reduction Responses — Eight Syringe Services Programs, Maryland, November 2021–August 2022
Open accessThe DOI matches its Crossref record.
Abstract
in partnership with the Maryland Department of Health Center for Harm Reduction Services (CHRS).** All test results were available within 48 hours. Among the 496 paraphernalia samples collected, 367 (74.0%) tested positive for an opioid, and 364 (99.2%) of these samples contained fentanyl or fentanyl analogs. Approximately four fifths of fentanyl-positive samples also tested positive for the veterinary medicine xylazine, a sedative that when combined with opioids might increase the potential for fatal respiratory depression and soft tissue infections when injected (1). For 248 of the 496 samples, SSP participants also completed a questionnaire about the drugs they had intended to purchase. Among the 212 participants who had intended to buy an opioid, 87.7% were exposed to fentanyl, fentanyl analogs, or both, and 85.8% were unknowingly exposed to xylazine. Results improved awareness of fentanyl and xylazine among SSP staff members and galvanized efforts to enhance SSPs' wound care services for participants experiencing soft tissue injuries possibly associated with injecting xylazine. Rapid analysis of drug paraphernalia can provide timely data on changing illicit drug markets that can be used to mitigate the harms of drug use more effectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fentanyl Test Strips for Harm Reduction: A Scoping Review
Kutscher, E., Barber Grossi, M., LaPolla, F., & Lee, J. D. (2024) · Journal of Addiction Medicine · doi:10.1097/adm.0000000000001321 · Cited by 30
Comprehensive method to detect nitazene analogues and xylazine in wastewater
Keller, E. L., Peake, B., Simpson, B. S., White, J. M., & Gerber, C. (2025) · Environmental Science and Pollution Research · doi:10.1007/s11356-025-36425-0 · Cited by 13
“In one study from the USA, xylazine was detected in approximately 80% of drug paraphernalia samples containing fentanyl or fentanyl analogues (Russell et al. 2023).”
Keller, E. L., Peake, B., Simpson, B. S., Longo, M., Trobbiani, S., White, J. M., & Gerber, C. (2026) · Drug and Alcohol Review · doi:10.1111/dar.70010 · Cited by 3
“Xylazine detections in seized drug material, paraphernalia and toxicology samples have been increasing dramatically in the USA [13, 18].”
Metadata
- Authors
- Russell, E., Sisco, E., Thomson, A., Lopes, J., Rybak, M., Burnett, M., Heilman, D., Appley, M. G., & Gladden, R. M.
- Venue
- MMWR. Morbidity and Mortality Weekly Report
- Published
- 2023-04-28
- Volume
- 72
- Issue
- 17
- Pages
- 458-462
- ISSN
- 0149-2195 (ISSN-L)
- 1545-861X
- OpenAlex
- W4367174282
- Cited by
- 58
- References
- 0
- FWCI
- 9.70
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.