Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 198

The DOI matches its Crossref record.

Energy Saving Lighting Control Systems for Open-Plan Offices: A Field Study

Galasiu, Anca D., Newsham, Guy R., Suvagau, Cristian, Sander, Daniel M. · 2007 · LEUKOS

Abstract

We conducted a field study in a deep-plan office building equipped with suspended direct-indirect luminaires located centrally in cubicle workstations. In order to reduce lighting energy use, the luminaires employed integral occupancy sensors and light sensors (daylight harvesting), as well as individual dimming control accessed through occupants' computer screens. Data were collected from 86 workstations over a year to examine the energy savings and power reduction attributable to the controls, and how the controls were used. An awareness campaign that used e-mail reminders to encourage the occupants to use the individual control feature of the lighting system was also conducted. Results indicate that the lighting system generated substantial energy savings and peak power reductions compared to a conventional fluorescent lighting system installed on a neighboring floor. The installed lighting power was 42 percent lower than that of the conventional system. The three controls combined saved 42 to 47 percent in lighting energy use compared to the same lights used at full power during work-hours; this translated into overall savings of 67 to 69 percent compared to the conventional lighting system. If the three lighting controls systems had been installed separately, occupancy sensors would have saved, on average, 35 percent if used alone, light sensors (daylight harvesting) 20 percent, and individual dimming 11 percent. The light sensor savings were, as expected, higher in perimeter workstations, and would have matched the performance of the occupancy sensors with some modifications to the control parameters. The average daily peak power demand for lighting was also reduced by a similar amount, which resulted in an average effective lighting power density of only 3 W/m2. Although not detailed in this paper, surveys indicated that the studied lighting system was also associated with higher occupant satisfaction. This was likely due to the individual dimming control, although use of this control beyond an initial preferred setting was rare.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1582/leukos.2007.04.01.001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 198

Metadata

Authors
Galasiu, A. D., Newsham, G. R., Suvagau, C., & Sander, D. M.
Venue
LEUKOS
Published
2007-07-01
Volume
4
Issue
1
Pages
7-29
ISSN
  • 1550-2716 (ISSN-L)
  • 1550-2724
OpenAlex
W1577582053
Cited by
198
References
0
FWCI
22.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Energy Saving Lighting Control Systems for Open-Plan Offices: A Field Study. https://app.cochat.ai/papers/10.1582/leukos.2007.04.01.001
The paper
Galasiu, A. D., Newsham, G. R., Suvagau, C., & Sander, D. M. (2007). Energy Saving Lighting Control Systems for Open-Plan Offices: A Field Study. LEUKOS. https://doi.org/10.1582/leukos.2007.04.01.001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.