Preliminary Results After Application of Absorbable Metal Stents in Patients With Critical Limb Ischemia
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
PURPOSE: To report the preliminary 3-month follow-up of a recently developed absorbable metal stent (AMS) for treatment of infrapopliteal lesions in patients with critical limb ischemia (CLI). METHODS: Between December 2003 and January 2004, 20 patients (10 men; mean age 76 years, range 59-96) with symptomatic critical limb ischemia (CLI) due to high-grade (80% to 100%) infrapopliteal stenoses received 1 or 2 AMS devices for suboptimal angioplasty. Clinical examination and color-flow duplex imaging were performed in all patients at discharge and at 1 and 3 months. RESULTS: Angiographic procedural success was achieved in all 20 patients. One patient died (non-procedure-related) during the periprocedural period. Three months after the procedure, primary clinical patency was 89.5% (17/19). No major or minor amputation was necessary in any of the patients, yielding a limb salvage rate of 100%. The average improvement in Rutherford class was 2.3 at the 3-month assessment. A comparison of postprocedural and 1-month color-flow duplex ultrasound and magnetic resonance images clearly indicated the ongoing absorption process of the AMS. CONCLUSIONS: After 3 months, the primary clinical patency and limb salvage rates suggest a potentially promising performance of these AMS devices in the treatment of below-knee lesions in CLI patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Self-citationInitial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Peuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G. (2001) · Heart · doi:10.1136/heart.86.5.563 · Cited by 569
Biodegradable stents as a platform to drug loading
Tsuji, T., Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Hata, T., Nakamura, T., Fujita, S., Takeda, S., Motohara, S., et al. (2003) · International Journal of Cardiovascular Interventions · doi:10.1080/14628840304609 · Cited by 90
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Chen, Q., & Thouas, G. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.10.001 · Cited by 2,398
Recent advances on the development of magnesium alloys for biodegradable implants
Chen, Y., Xu, Z., Smith, C., & Sankar, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.005 · Cited by 1,236
Erbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60853-8 · Cited by 907
Self-citationMgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants
Zberg, B., Uggowitzer, P. J., & Löffler, J. F. (2009) · Nature Materials · doi:10.1038/nmat2542 · Cited by 899
Metadata
- Authors
- Peeters, P., Bosiers, M., Verbist, J., Deloose, K., & Heublein, B.
- Venue
- Journal of Endovascular Therapy
- Published
- 2005-02
- Volume
- 12
- Issue
- 1
- Pages
- 1-5
- ISSN
- 1526-6028 (ISSN-L)
- 1545-1550
- OpenAlex
- W2089696104
- Cited by
- 275
- References
- 4
- FWCI
- 14.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.