PURPOSE: To evaluate the feasibility, safety, and effectiveness of prophylactically placed noninvasive transcutaneous temporary pacemakers (NTP) to prevent angioplasty-induced bradycardia and hypotension during carotid angioplasty and stenting (CAS). METHODS: The preventive use of NTPs was evaluated in 31 CAS procedures performed at 3 institutions in 30 patients considered to be at high risk for developing angioplasty-induced bradycardia. Twenty-four cases in 23 patients (20 men; mean age 72 years, range 56-85) requiring intraprocedural pacing due to angioplasty-induced bradycardia were included in this study. Pacemakers were set to capture a heart rate <60 beats/min based on the basal heart rate. RESULTS: Noninvasive pacing was technically effective in producing electrical ventricular responses and was hemodynamically effective in most patients. All patients were easily and comfortably stimulated at amplitudes <50 mA (usually 30). There were no complications related to either pacemaker placement or performance. CONCLUSION: The prophylactic use of a noninvasive transcutaneous pacemaker for expected bradycardia during CAS appears to be safe and effective in preventing intraprocedural bradycardia and hypotension, with a decrease in additional pharmacological support during the procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 32
- A. M. Malek, R. T. Higashida, and C. C. Phatouros .et al.Stent angioplasty for cervical carotid artery stenosis in high-risk symptomatic NASCET-ineligible patients., Stroke, 2000 .31 :3029 –3033 . · DOI
- A. Dietz, J. Berkefeld, and J. G. Theron .et al.Endovascular treatment of symptomatic carotid stenosis using stent placement: long-term follow-up of patients with a balanced surgical risk/benefit ratio., Stroke, 2001 .32 :1855 –1859 . · doi:10.1161/01.str.32.8.1855
- M. A. Bettmann, B. T. Katzen, and J. Whisnant .et al.Carotid stenting and angioplasty: a statement for healthcare professionals from the Councils on Cardiovascular Radiology, Stroke, Cardio-Thoracic and Vascular Surgery, Epidemiology and Prevention, and Clinical Cardiology, American Heart Association., Stroke, 1998 .29 :336 –338 . · DOI
- H. G. Beebe, J. P. Archie, and W. H. Baker .et al.Concern about safety of carotid angioplasty., Stroke, 1996 .27 :197 –198 . · DOI
- M. M. Brown, G. Venables, and A. Clifton .et al.Carotid endarterectomy vs carotid angioplasty., Lancet, 1997 .349 :880 –881 . · DOI
- J. Grotta, Elective stenting of extracranial carotid arteries., Circulation, 1997 .95 :303 –305 . · doi:10.1161/01.cir.95.2.303
- R. L. Bush, P. H. Lin, and C. C. Bianco .et al.Reevaluation of temporary transvenous cardiac pacemaker usage during carotid angioplasty and stenting: a safe and valuable adjunct., Vasc Endovasc Surg, 2004 .38 :229 –235 . · doi:10.1177/153857440403800306
- J. S. Harrop, A. D. Sharan, and R. P. Benitez .et al.Prevention of carotid angioplasty-induced bradycardia and hypotension with temporary venous pacemakers., Neurosurgery, 2001 .49 :814 –820 . · doi:10.1227/00006123-200110000-00006
- A. I. Qureshi, A. R. Luft, and M. Sharma .et al.Frequency and determinants of postprocedural hemodynamic instability after carotid angioplasty and stenting., Stroke, 1999 .30 :2086 –2093 . · DOI · Paper page
- F. O. Mendelsohn, N. J. Weissman, and R. J. Lederman .et al.Acute hemodynamic changes during carotid artery stenting., Am J Cardiol, 1998 .82 :1077 –1081 . · DOI
- 10.1583/1074-6218(1997)004<0326:ESFCAO>2.0.CO;2 · doi:10.1583/1074-6218(1997)004<0326:esfcao>2.0.co;2
- A. Gupta, A. Bhatia, and A. Ahuja .et al.Carotid stenting in patients older than 65 years with inoperable carotid artery disease: a single-center experience., Catheter Cardiovasc Interv, 2000 .50 :1 –8 . · doi:10.1002/(sici)1522-726x(200005)50:1<1::aid-ccd1>3.0.co;2-r
- J. S. Yadav, G. S. Roubin, and S. Iyer .et al.Elective stenting of the extracranial carotid arteries., Circulation, 1997 .95 :376 –381 . · DOI · Paper page
- G. Dangas, J. R. Laird, and L. F. Satler .et al.Postprocedural hypotension after carotid artery stent placement: predictors and short- and long-term clinical outcomes., Radiology, 2000 .215 :677 –683 . · doi:10.1148/radiology.215.3.r00jn04677
- K. Laczika, F. Thalhammer, and G. Locker .et al.Safe and efficient emergency transvenous ventricular pacing via the right supraclavicular route., Anesth Analg, 2000 .90 :784 –789 . · doi:10.1213/00000539-200004000-00003
- W. Mlekusch, M. Schillinger, and S. Sabeti .et al.Hypotension and bradycardia after elective carotid stenting: frequency and risk factors., J Endovasc Ther, 2003 .10 :851 –859 . · DOI
- G. P. Teitelbaum, M. A. Lefkowitz, and S. L. Giannotta .Carotid angioplasty and stenting in high-risk patients., Surg Neurol, 1998 .50 :300 –312 . · DOI
- C. C. Phatouros, R. T. Higashida, and A. M. Malek .et al.Carotid artery stent placement for atherosclerotic disease: rationale, technique, and current status., Radiology, 2000 .217 :26 –41 . · DOI
- P. M. Zoll, Resuscitation of the heart in ventricular standstill by external electric stimulation., N Engl J Med, 1952 .247 :768 –771 . · DOI · Paper page
- B. A. Gould, and A. J. Marshall .Noninvasive temporary pacemakers., Pacing Clin Electrophysiol, 1988 .11 :1331 –1335 . · doi:10.1111/j.1540-8159.1988.tb03996.x
- P. M. Zoll, R. H. Zoll, and A. H. Belgard .External noninvasive electric stimulation of the heart., Crit Care Med, 1981 .9 :393 –394 . · doi:10.1097/00003246-198105000-00021
- P. M. Zoll, R. H. Zoll, and R. H. Falk .et al.External noninvasive temporary cardiac pacing: clinical trials., Circulation, 1985 .71 :937 –944 . · DOI · Paper page
- R. H. Falk, P. M. Zoll, and R. H. Zoll .Safety and efficacy of noninvasive cardiac pacing. A preliminary report., N Engl J Med, 1983 .309 :1166 –1168 . · doi:10.1056/nejm198311103091907
- Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis., N Engl J Med, 1991 .325 :445 –453 . · DOI · Paper page
- N. S. Cayne, P. L. Faries, and S. M. Trocciola .et al.Carotid angioplasty and stent-induced bradycardia and hypotension: impact of prophylactic atropine administration and prior carotid endarterectomy., J Vasc Surg, 2005 .41 :956 –961 . · DOI
- G. Pappada, E. Beghi, and R. Marina .et al.Hemodynamic instability after extracranial carotid stenting., Acta Neurochir (Wien), 2006 .148 :639 –645 . · doi:10.1007/s00701-006-0752-2
- J. H. Wong, J. M. Findlay, and M. E. Suarez-Almazor .Hemodynamic instability after carotid endarterectomy: risk factors and associations with operative complications., Neurosurgery, 1997 .41 :35 –41 . · doi:10.1097/00006123-199707000-00009
- A. I. Qureshi, A. R. Luft, and D. K. Lopes .et al.Postoperative hypotension after carotid angioplasty and stenting: report of three cases., Neurosurgery, 1999 .44 :1320 –1323 . · DOI
- E. Tarlov, H. Schmidek, and R. M. Scott .et al.Reflex hypotension following carotid endarterectomy: mechanism and management., J Neurosurg, 1973 .39 :323 –327 . · doi:10.3171/jns.1973.39.3.0323
- J. C. Luck, and M. L. Markel .Clinical applications of external pacing: a renaissance? Pacing Clin Electrophysiol, 1991 .14 :1299 –1316 . · doi:10.1111/j.1540-8159.1991.tb02870.x
- J. L. Austin, L. K. Preis, and R. S. Crampton .et al.Analysis of pacemaker malfunction and complications of temporary pacing in the coronary care unit., Am J Cardiol, 1982 .49 :301 –306 . · DOI
- N. G. Pandian, B. D. Kosowsky, and V. Gurewich .Transfemoral temporary pacing and deep vein thrombosis., Am Heart J, 1980 .100 :847 –851 . · DOI
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.043 · Cited by 337
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000627 · Cited by 160
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Metadata
- Authors
- Im, S.-H., Han, M. H., Kim, S. H., & Kwon, B. J.
- Venue
- Journal of Endovascular Therapy
- Published
- 2008-02
- Volume
- 15
- Issue
- 1
- Pages
- 110-116
- ISSN
- 1526-6028 (ISSN-L)
- 1545-1550
- OpenAlex
- W1992577557
- Cited by
- 26
- References
- 0
- FWCI
- 1.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.