Nitinol Stent Implantation in Long Superficial Femoral Artery Lesions: 12-Month Results of the DURABILITY I Study

Bosiers, Marc, Torsello, Giovanni, Gißler, Hans-Martin, Ruef, Johannes, Müller-Hülsbeck, Stefan, Jahnke, Thomas, Peeters, Patrick, Daenens, Kim, Lammer, Johannes, Schroë, Herman, Mathias, Klaus, Koppensteiner, Renate, Vermassen, Frank, Scheinert, Dierk·2009·Journal of Endovascular Therapy

Abstract

PURPOSE: To evaluate the long-term efficacy and integrity of the PROTEGE EverFlex stent in superficial femoral artery (SFA) lesions in symptomatic patients with peripheral artery disease (PAD). METHODS: A prospective, multicenter, nonrandomized study enrolled 151 subjects (111 men; mean age 67.8 years, range 42-93) undergoing percutaneous treatment of de novo, restenotic, or reoccluded SFA lesions between August 11, 2006, and June 26, 2007. Subjects were scheduled to receive a single stent and be evaluated through 12 months following the implant procedure. Occlusions were present in 40% of the patients. Mean lesion length was 96.4 mm (range 10-150). RESULTS: A total of 161 stents (158 EverFlex) were implanted in the 151 patients: single stents in 93.4% (141/151) and a second stent in 6.6% (10/151). One-year follow-up information was available for 88.7% (134/151) of the study participants; of the remaining 17 subjects, 6 subjects withdrew from the study, 2 were lost to follow-up, and 9 died. Freedom from restenosis data were available for 99.3% (133/134) of the subjects who completed a 12-month follow-up visit. The mean Rutherford classification fell from 2.8+/-0.8 (range 1-5) at baseline to 0.6+/-1.1 (range 0-5) at 12 months. The mean ankle-brachial index rose from 0.6+/-0.2 (range 0-1.4) at baseline to 0.9+/-0.2 (range 0-1.2) at 12 months. The rates for freedom from >50% restenosis at 6 and 12 months were 91.3% (95% CI 84.9% to 95.2%) and 72.2% (95% CI 63.8% to 79.6%), respectively. The freedom from target lesion revascularization rate at 12 months was 79.1% (95% CI 71.2% to 85.6%). The 1-year stent fracture rate was 8.1% (95% CI 4.0% to 14.4%). CONCLUSION: The high freedom from >50% restenosis and low fracture rate at 12 months suggests that the PROTEGE EverFlex stent offers a safe and acceptably efficacious means of treating SFA lesions in symptomatic subjects with PAD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1583/08-2676.1

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 211

Metadata

Authors
Bosiers, M., Torsello, G., Gißler, H.-M., Ruef, J., Müller-Hülsbeck, S., Jahnke, T., Peeters, P., Daenens, K., Lammer, J., Schroë, H., Mathias, K., Koppensteiner, R., Vermassen, F., & Scheinert, D.
Venue
Journal of Endovascular Therapy
Published
2009-06
Volume
16
Issue
3
Pages
261-269
ISSN
  • 1526-6028 (ISSN-L)
  • 1545-1550
OpenAlex
W2136537594
Cited by
211
References
1
FWCI
11.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nitinol Stent Implantation in Long Superficial Femoral Artery Lesions: 12-Month Results of the DURABILITY I Study. https://app.cochat.ai/papers/10.1583/08-2676.1
The paper
Bosiers, M., Torsello, G., Gißler, H.-M., Ruef, J., Müller-Hülsbeck, S., Jahnke, T., Peeters, P., Daenens, K., Lammer, J., Schroë, H., Mathias, K., Koppensteiner, R., Vermassen, F., & Scheinert, D. (2009). Nitinol Stent Implantation in Long Superficial Femoral Artery Lesions: 12-Month Results of the DURABILITY I Study. Journal of Endovascular Therapy. https://doi.org/10.1583/08-2676.1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.