Pulmonary vaccine delivery
The DOI matches its Crossref record.
Abstract
This review will discuss developments in the field of pulmonary vaccine delivery. The possibilities of adopting aerosol-generation technology and specific pharmaceutical formulations for the purpose of pulmonary immunization are described. Aerosol-generation systems might offer advantages with respect to vaccine stability and antigenicity. Adjuvants and their inclusion in vaccine-delivery systems are described. Other formulation components, such as surfactants, particulate systems and dispersion of the aerosols are detailed in this paper. The noninvasive, relatively safe and low-cost nature of pulmonary delivery may provide great benefits to the public health vaccination campaign.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pharmaceutical Particle Engineering via Spray Drying
Vehring, R. (2008) · Pharmaceutical Research · doi:10.1007/s11095-007-9475-1 · Cited by 1,691
Therapeutic efficacy of nanoparticles and routes of administration
Chenthamara, D., Subramaniam, S., Ramakrishnan, S. G., Krishnaswamy, S., Essa, M. M., Lin, F.-H., & Qoronfleh, M. W. (2019) · Biomaterials Research · doi:10.1186/s40824-019-0166-x · Cited by 1,055
Advances in transcutaneous vaccine delivery: Do all ways lead to Rome?
Bal, S. M., Ding, Z., van Riet, E., Jiskoot, W., & Bouwstra, J. A. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.09.018 · Cited by 199
Combinatorial development of nebulized mRNA delivery formulations for the lungs
Jiang, A. Y., Witten, J., Raji, I. O., Eweje, F., MacIsaac, C., Meng, S., Oladimeji, F. A., Hu, Y., Manan, R. S., Langer, R., et al. (2024) · Nature Nanotechnology · doi:10.1038/s41565-023-01548-3 · Cited by 185
Potential of Nasopharynx-associated Lymphoid Tissue for Vaccine Responses in the Airways
Brandtzaeg, P. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201011-1783oc · Cited by 181
Immunization by a bacterial aerosol
Garcia-Contreras, L., Wong, Y.-L., Muttil, P., Padilla, D., Sadoff, J., DeRousse, J., Germishuizen, W. A., Goonesekera, S., Elbert, K., Bloom, B. R., et al. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800043105 · Cited by 145
“Published studies of inhaled vaccines for measles, influenza, and TB (2) have mostly involved nebulized solutions, a process that necessitates large volumes of water with long administration times; dried forms of vaccines, as formed traditionally by freeze drying and recently by spray drying (15), present an alternati…”
BackgroundSelf-citationThomas, C., Gupta, V., & Ahsan, F. (2009) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2009.06.006 · Cited by 79
Pravetoni, M., Keyler, D. E., Raleigh, M. D., Harris, A. C., LeSage, M. G., Mattson, C. K., Pettersson, S., & Pentel, P. R. (2011) · Biochemical Pharmacology · doi:10.1016/j.bcp.2011.02.004 · Cited by 33
“Intranasal or direct pulmonary immunization might be of interest to further explore whether sufficient pulmonary mucosal nicotine-specific IgA levels can be produced in this manner to influence nicotine absorption [40,41].”
Metadata
- Authors
- Lu, D., & Hickey, A. J.
- Venue
- Expert Review of Vaccines
- Publisher
- Informa UK Limited
- Published
- 2007-04
- Volume
- 6
- Issue
- 2
- Pages
- 213-226
- ISSN
- 1476-0584 (ISSN-L)
- 1744-8395
- OpenAlex
- W2169383781
- Cited by
- 142
- References
- 0
- FWCI
- 5.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.