Influence of sterilisation methods on collagen-based devices stability and properties
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Sterilisation is essential for any implantable medical device in order to prevent infection in patients. The selection of the most appropriate sterilisation method depends on the nature and the physical state of the material to be sterilised; the influence of the sterilisation method on the properties of the device; and the type of the potential contaminant. In this context, herein we review the influence of ethylene oxide, γ-irradiation, e-beam irradiation, gas plasma, peracetic acid and ethanol on structural, biomechanical, biochemical and biological properties of collagen-based devices. Data to-date demonstrate that chemical approaches are associated with cytotoxicity, whilst physical methods are associated with degradation, subject to the device physical characteristics. Thus, the sterilisation method of choice is device dependent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Collagen—emerging collagen based therapies hit the patient
Abou Neel, E. A., Bozec, L., Knowles, J. C., Syed, O., Mudera, V., Day, R., & Hyun, J. K. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.08.010 · Cited by 296
Cited by
The Collagen Suprafamily: From Biosynthesis to Advanced Biomaterial Development
Sorushanova, A., Delgado, L. M., Wu, Z., Shologu, N., Kshirsagar, A., Raghunath, R., Mullen, A. M., Bayon, Y., Pandit, A., Raghunath, M., et al. (2019) · Advanced Materials · doi:10.1002/adma.201801651 · Cited by 1,151
Self-citationProcessing of collagen based biomaterials and the resulting materials properties
Meyer, M. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0647-0 · Cited by 539
“The comparison between both methods showed no remarkable difference, but this technique is not as common as γ-irradiation [451, 458, 459].”
BackgroundMethodJoyce, K., Fabra, G. T., Bozkurt, Y., & Pandit, A. (2021) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-021-00512-8 · Cited by 316
Self-citationNovel Biomedical Applications of Crosslinked Collagen
Gu, L., Shan, T., Ma, Y.-X., Tay, F. R., & Niu, L. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.10.007 · Cited by 305
Delgado, L. M., Bayon, Y., Pandit, A., & Zeugolis, D. I. (2015) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2014.0290 · Cited by 272
Self-citation
Metadata
- Authors
- Delgado, L. M., Pandit, A., & Zeugolis, D. I.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2014-03-21
- Volume
- 11
- Issue
- 3
- Pages
- 305-314
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2087614005
- Cited by
- 70
- References
- 1
- FWCI
- 1.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.