Cited by 38Diabetes Management and ResearchDiabetes Treatment and ManagementPancreatic function and diabetes

Moving toward the ideal insulin for insulin pumps

Cengiz, Eda, Bode, Bruce, Van Name, Michelle, Tamborlane, William V·2016·Expert Review of Medical Devices

Abstract

Advances in insulin formulations have been important for diabetes management and achieving optimal glycemic control. Rapid-acting insulin analogs provide a faster time-action profile than regular insulin and are approved for use in pumps. However, the need remains for therapy to deliver a more physiologic insulin profile. New insulin formulations and delivery methods are in development, with the aim of accelerating insulin absorption to accomplish ultra-fast-acting insulin time-action profiles. Furthermore, the integration of continuous glucose monitoring with insulin pump therapy enables on-going adjustment of insulin delivery to optimize glycemic control throughout the day and night. These technological and pharmacological advances are likely to facilitate the development of closed-loop pump systems (i.e., artificial pancreas), and improve glycemic control and quality of life for patients with diabetes.

Integrity signals

Registry

Crossref · 10.1586/17434440.2016.1109442

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Insulin action can be delayed and vary between individuals and with different insulin analogues, which limits the ability of the AID system to respond promptly to rising glucose concentrations.

    “Insulin action can be delayed and vary between individuals and with different insulin analogues, which limits the ability of the AID system to respond promptly to rising glucose concentrations.105”

    From The future of type 1 diabetes therapy (2025) · cites this paper as [105]

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 94 · Cited by 38

Authors
Cengiz, E., Bode, B., Van Name, M., & Tamborlane, W. V.
Affiliations
  • Yale University (US)
  • Atlanta Diabetes Associates (US)
Corresponding author
Cengiz, Eda
Venue
Expert Review of Medical Devices
Published
2015-11-11
Volume
13
Issue
1
Pages
57-69
ISSN
  • 1743-4440 (ISSN-L)
  • 1745-2422
OpenAlex
W2221738370
Cited by
38
References
94
Citations by year
2025: 3 · 2024: 3 · 2023: 2 · 2022: 4 · 2021: 3 · 2020: 4 · 2019: 4 · 2018: 4 · 2017: 8 · 2016: 2 · 2015: 1
FWCI
0.75
Type
journal article
Language
en
Open access
closed
Locations
  • Expert Review of Medical Devices (publishedVersion)
  • PubMed (publishedVersion)
Funders
Novo Nordisk
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
  • Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
Keywords
insulin pump, insulin formulations, rapid-acting insulin analogs, insulin absorption, continuous glucose monitoring, artificial pancreas, glycemic control, diabetes management
MeSH terms
Amino Acid Sequence, Humans, Insulin, Insulin Infusion Systems, Molecular Sequence Data, Insulin, Short-Acting, Absorption, Physiological

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review