Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 183

The DOI matches its Crossref record.

Normal range values for thromboelastography in healthy adult volunteers

Open access
Scarpelini, S., Rhind, S.G., Nascimento, B., Tien, H., Shek, P.N., Peng, H.T., Huang, H., Pinto, R., Speers, V., Reis, M., Rizoli, S.B. · 2009 · Brazilian Journal of Medical and Biological Research

Abstract

Thromboelastography (TEG) provides a functional evaluation of coagulation. It has characteristics of an ideal coagulation test for trauma, but is not frequently used, partially due to lack of both standardized techniques and normal values. We determined normal values for our population, compared them to those of the manufacturer and evaluated the effect of gender, age, blood type, and ethnicity. The technique was standardized using citrated blood, kaolin and was performed on a Haemoscope 5000 device. Volunteers were interviewed and excluded if pregnant, on anticoagulants or having a bleeding disorder. The TEG parameters analyzed were R, K, alpha, MA, LY30, and coagulation index. All volunteers outside the manufacturer's normal range underwent extensive coagulation investigations. Reference ranges for 95% for 118 healthy volunteers were R: 3.8-9.8 min, K: 0.7-3.4 min, alpha: 47.8-77.7 degrees, MA: 49.7-72.7 mm, LY30: -2.3-5.77%, coagulation index: -5.1-3.6. Most values were significantly different from those of the manufacturer, which would have diagnosed coagulopathy in 10 volunteers, for whom additional investigation revealed no disease (81% specificity). Healthy women were significantly more hypercoagulable than men. Aging was not associated with hypercoagulability and East Asian ethnicity was not with hypocoagulability. In our population, the manufacturer's normal values for citrated blood-kaolin had a specificity of 81% and would incorrectly identify 8.5% of the healthy volunteers as coagulopathic. This study supports the manufacturer's recommendation that each institution should determine its own normal values before adopting TEG, a procedure which may be impractical. Consideration should be given to a multi-institutional study to establish wide standard values for TEG.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1590/s0100-879x2009001200015

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 183

Metadata

Authors
Scarpelini, S., Rhind, S. G., Nascimento, B., Tien, H., Shek, P. N., Peng, H. T., Huang, H., Pinto, R., Speers, V., Reis, M., & Rizoli, S. B.
Venue
Brazilian Journal of Medical and Biological Research
Published
2009-12
Volume
42
Issue
12
Pages
1210-1217
ISSN
  • 0100-879X (ISSN-L)
  • 1414-431X
OpenAlex
W2098624466
Cited by
183
References
0
FWCI
4.03
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Normal range values for thromboelastography in healthy adult volunteers. https://app.cochat.ai/papers/10.1590/s0100-879x2009001200015
The paper
Scarpelini, S., Rhind, S. G., Nascimento, B., Tien, H., Shek, P. N., Peng, H. T., Huang, H., Pinto, R., Speers, V., Reis, M., & Rizoli, S. B. (2009). Normal range values for thromboelastography in healthy adult volunteers. Brazilian Journal of Medical and Biological Research. https://doi.org/10.1590/s0100-879x2009001200015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.