The DOI matches its Crossref record.
Normal range values for thromboelastography in healthy adult volunteers
Open accessAbstract
Thromboelastography (TEG) provides a functional evaluation of coagulation. It has characteristics of an ideal coagulation test for trauma, but is not frequently used, partially due to lack of both standardized techniques and normal values. We determined normal values for our population, compared them to those of the manufacturer and evaluated the effect of gender, age, blood type, and ethnicity. The technique was standardized using citrated blood, kaolin and was performed on a Haemoscope 5000 device. Volunteers were interviewed and excluded if pregnant, on anticoagulants or having a bleeding disorder. The TEG parameters analyzed were R, K, alpha, MA, LY30, and coagulation index. All volunteers outside the manufacturer's normal range underwent extensive coagulation investigations. Reference ranges for 95% for 118 healthy volunteers were R: 3.8-9.8 min, K: 0.7-3.4 min, alpha: 47.8-77.7 degrees, MA: 49.7-72.7 mm, LY30: -2.3-5.77%, coagulation index: -5.1-3.6. Most values were significantly different from those of the manufacturer, which would have diagnosed coagulopathy in 10 volunteers, for whom additional investigation revealed no disease (81% specificity). Healthy women were significantly more hypercoagulable than men. Aging was not associated with hypercoagulability and East Asian ethnicity was not with hypocoagulability. In our population, the manufacturer's normal values for citrated blood-kaolin had a specificity of 81% and would incorrectly identify 8.5% of the healthy volunteers as coagulopathic. This study supports the manufacturer's recommendation that each institution should determine its own normal values before adopting TEG, a procedure which may be impractical. Consideration should be given to a multi-institutional study to establish wide standard values for TEG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Disorders of coagulation in pregnancy
Katz, D., & Beilin, Y. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev374 · Cited by 289
Stravitz, R. T., Lisman, T., Luketic, V. A., Sterling, R. K., Puri, P., Fuchs, M., Ibrahim, A., Lee, W. M., & Sanyal, A. J. (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2011.04.020 · Cited by 268
Larsen, O. H., Fenger-Eriksen, C., Christiansen, K., Ingerslev, J., & Sørensen, B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318220755c · Cited by 117
Stravitz, R. T., Fontana, R. J., Meinzer, C., Durkalski‐Mauldin, V., Hanje, A. J., Olson, J., Koch, D., Hamid, B., Schilsky, M. L., McGuire, B., et al. (2021) · Hepatology · doi:10.1002/hep.31767 · Cited by 50
Ni, L., Xue, P., An, C., Yu, X., Qu, J., Yao, Y., & Li, Y. (2021) · Journal of Healthcare Engineering · doi:10.1155/2021/7119779 · Cited by 48
Metadata
- Authors
- Scarpelini, S., Rhind, S. G., Nascimento, B., Tien, H., Shek, P. N., Peng, H. T., Huang, H., Pinto, R., Speers, V., Reis, M., & Rizoli, S. B.
- Venue
- Brazilian Journal of Medical and Biological Research
- Publisher
- FapUNIFESP (SciELO)
- Published
- 2009-12
- Volume
- 42
- Issue
- 12
- Pages
- 1210-1217
- ISSN
- 0100-879X (ISSN-L)
- 1414-431X
- OpenAlex
- W2098624466
- Cited by
- 183
- References
- 0
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Normal range values for thromboelastography in healthy adult volunteers. https://app.cochat.ai/papers/10.1590/s0100-879x2009001200015
- The paper
- Scarpelini, S., Rhind, S. G., Nascimento, B., Tien, H., Shek, P. N., Peng, H. T., Huang, H., Pinto, R., Speers, V., Reis, M., & Rizoli, S. B. (2009). Normal range values for thromboelastography in healthy adult volunteers. Brazilian Journal of Medical and Biological Research. https://doi.org/10.1590/s0100-879x2009001200015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.