Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index; 3 of the 26 sources its claims cite were checked for support.

Performance of the dipstick screening test as a predictor of negative urine culture

Open access

Abstract

OBJECTIVE: To investigate whether the urine dipstick screening test can be used to predict urine culture results. METHODS: A retrospective study conducted between January and December 2014 based on data from 8,587 patients with a medical order for urine dipstick test, urine sediment analysis and urine culture. Sensitivity, specificity, positive and negative predictive values were determined and ROC curve analysis was performed. RESULTS: The percentage of positive cultures was 17.5%. Nitrite had 28% sensitivity and 99% specificity, with positive and negative predictive values of 89% and 87%, respectively. Leukocyte esterase had 79% sensitivity and 84% specificity, with positive and negative predictive values of 51% and 95%, respectively. The combination of positive nitrite or positive leukocyte esterase tests had 85% sensitivity and 84% specificity, with positive and negative predictive values of 53% and 96%, respectively. Positive urinary sediment (more than ten leukocytes per microliter) had 92% sensitivity and 71% specificity, with positive and negative predictive values of 40% and 98%, respectively. The combination of nitrite positive test and positive urinary sediment had 82% sensitivity and 99% specificity, with positive and negative predictive values of 91% and 98%, respectively. The combination of nitrite or leukocyte esterase positive tests and positive urinary sediment had the highest sensitivity (94%) and specificity (84%), with positive and negative predictive values of 58% and 99%, respectively. Based on ROC curve analysis, the best indicator of positive urine culture was the combination of positives leukocyte esterase or nitrite tests and positive urinary sediment, followed by positives leukocyte and nitrite tests, positive urinary sediment alone, positive leukocyte esterase test alone, positive nitrite test alone and finally association of positives nitrite and urinary sediment (AUC: 0.845, 0.844, 0.817, 0.814, 0.635 and 0.626, respectively). CONCLUSION: A negative urine culture can be predicted by negative dipstick test results. Therefore, this test may be a reliable predictor of negative urine culture. OBJETIVO: Verificar se a triagem de urina por fitas reativas é capaz de predizer a cultura de urina. Métodos Estudo retrospectivo realizado entre janeiro e dezembro de 2014 com 8.587 pacientes, com solicitação médica de triagem de urina (fita), sedimento urinário e cultura de urina. FORAM ANALISADOS: sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e curva ROC. RESULTADOS: Foram positivas 17,5% das culturas. O nitrito apresentou sensibilidade de 28% e especificidade de 99%. O valor preditivo positivo foi de 89% e o valor preditivo negativo de 87%. Esterase apresentou sensibilidade de 79% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram de 51% e 95%, respectivamente. A combinação de nitrito ou esterase positivos apresentou sensibilidade de 85% e especificidade de 84%. Valor preditivo positivo e valor preditivo negativo foram, respectivamente, 53% e 96%. O sedimento positivo (mais de dez leucócitos por microlitro) apresentou sensibilidade de 92% e especificidade de 71%. O valor preditivo positivo foi 40% e o negativo, 98%. A combinação de nitrito e sedimento urinário positivos apresentou sensibilidade de 82% e especificidade de 99%. Os valores preditivos positivo e negativo foram 91% e 98%, respectivamente. Para o nitrito ou esterase positivos mais os leucócitos positivos, a sensibilidade foi de 94% e a especificidade de 84%. O valor preditivo positivo foi de 58% e o negativo foi de 99%. Com base na curva ROC, o melhor indicador de urocultura positiva foi a associação entre a esterase ou nitrito positivos na fita mais os leucócitos positivos no sedimento, seguido por nitrito e esterase positivos, sedimento urinário positivo isolado, esterase positiva isolada, nitrito positivo isolado e, finalmente, pela associação entre nitrito e sedimento urinário positivos (AUC: 0,845, 0,844, 0,817, 0,814, 0,635 e 0,626, respectivamente). CONCLUSÃO: Uma urocultura negativa pode ser prevista com resultados negativos na fita. Portanto, este teste pode ser um preditor confiável de urocultura negativa.

Overview

CoChat Summary

TL;DR

This retrospective study of 8,587 emergency-department patients found that negative dipstick urine screening results could predict negative urine culture, with the authors concluding it may help avoid unnecessary culture and urinalysis. Leukocyte esterase performed better than nitrite alone, and combining dipstick with urinary sediment improved prediction further.

Key findings

  • Of 8,587 patients, 1,604 urine cultures were positive, and the overall positive culture rate was reported as 17.5%; 267 cases (2.7%) had negative dipstick results but positive culture.
  • For predicting positive urine culture, nitrite alone had 28% sensitivity, 99% specificity, PPV 89%, and NPV 87%; leukocyte esterase alone had 79% sensitivity, 84% specificity, PPV 51%, and NPV 95%.
  • Combining positive nitrite or leukocyte esterase yielded 85% sensitivity, 84% specificity, PPV 53%, and NPV 96%; adding positive urinary sediment increased sensitivity to 94% and NPV to 99% (specificity 84%, PPV 58%).
  • ROC analysis ranked the best indicator of positive culture as positive nitrite or leukocyte esterase plus positive urinary sediment (AUC 0.845), followed closely by positive leukocyte esterase or nitrite alone (AUC 0.844).

Methods

  • Retrospective laboratory-data study from January to December 2014 in 8,587 emergency department patients; no exclusion criteria were used, and all had dipstick test, urinalysis with sediment analysis, and urine culture ordered.
  • Midstream voided urine samples were collected; dipstick testing was done in the emergency department, while urinalysis and cultures were refrigerated and sent to the central laboratory within 8 hours.
  • Main analysis: sensitivity, specificity, PPV, NPV, and ROC curve analysis for dipstick parameters and combinations, using urine culture positivity defined as ≥10^5 CFU/mL of a single microorganism.

Limitations

  • The paper explicitly states a limitation of retrospective analysis of laboratory data.
  • Clinical features were not taken into account, and analysis was based exclusively on laboratory parameters, which limits clinical interpretation of the findings.
  • The study was restricted to a single emergency-department laboratory dataset, so generalizability beyond this setting is not stated in the paper.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1590/s1679-45082017ao3936

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 ROC curve
Figure 1 ROC curveCC BY · PubMed Central

Verification

Claims the paper makes

2 Valid · 1 Not valid · 10 Not checked · 32 Own results and interpretations

21 more claims

Create a free account to see all 45 claims and to verify the 3 references still open.

See all claims — free account
  • It may state two separate claims as one. 15
  • Probably not a substantial claim. 10

Create a free account to see these claims.

Citations

Cites

Show all 32 references

Cited by

See all 33

Metadata

Authors
Marques, A. G., Doi, A. M., Pasternak, J., Damascena, M. D. S., França, C. N., & Martino, M. D. V.
Affiliations
  • Hospital Israelita Albert Einstein (BR)
  • Hospital Israelita Albert Einstein, Brazil
  • Universidade de Santo Amaro (BR)
Venue
Einstein (São Paulo)
Published
2017-03
Volume
15
Issue
1
Pages
34-39
ISSN
1679-4508 (ISSN-L)
OpenAlex
W2605984098
Cited by
33
References
32
Citations by year
2026: 4 · 2024: 6 · 2023: 2 · 2022: 6 · 2021: 3 · 2020: 5 · 2019: 5 · 2018: 2
FWCI
2.57
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Einstein (São Paulo) (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (publishedVersion, other-oa)
  • Americanae (AECID Library) (submittedVersion, cc-by-nc)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Urology › Urinary Tract Infections Management
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Pediatric Urology and Nephrology Studies
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
Keywords
urine dipstick, urine culture, urinary tract infection, nitrite, leukocyte esterase, urine sediment, diagnostic accuracy, negative predictive value, screening test, sensitivity and specificity, predictive value, receiver operating characteristic
MeSH terms
Adult, Analysis of Variance, Bacteriuria, Child, Preschool, Esterases, Humans, Leukocytes, Male, Middle Aged, Nitrites, Reference Standards, Reference Values, Retrospective Studies, Sensitivity and Specificity, Urinary Tract Infections, Urine, Colony Count, Microbial, Urinalysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (qwen3.8-omni-flash).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of the dipstick screening test as a predictor of negative urine culture. https://app.cochat.ai/papers/10.1590/s1679-45082017ao3936
The paper
Marques, A. G., Doi, A. M., Pasternak, J., Damascena, M. D. S., França, C. N., & Martino, M. D. V. (2017). Performance of the dipstick screening test as a predictor of negative urine culture. Einstein (São Paulo). https://doi.org/10.1590/s1679-45082017ao3936

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.