CoChat

A Clinical Comparison of Calculated versus Direct Measurement of Low‐Density Lipoprotein Cholesterol Level

Lindsey, Cameron C., Graham, Maqual R., Johnston, Thomas P., Kiroff, Chelsea G., Freshley, Anna · 2004 · Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy
Cited by 59

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Study Objectives. To determine if, and to what extent, the low‐density lipoprotein cholesterol (LDL) level is underestimated when it is calculated by the Friedewald formula compared with the LDL level measured by a direct method. A secondary objective was to determine and compare the percentages of patients meeting LDL goal using each of these two methods. Design. Retrospective chart review. Setting. Kansas City Veterans Affairs Medical Center. Subjects. Patients aged 18 years or older and whose laboratory results reflected a complete lipid profile for 1 year. Measurement and Main Results. Calculated LDL level (C‐LDL) was derived using the Friedewald formula and was compared with Wako method–derived direct LDL level (D‐LDL) to ascertain whether a positive correlation existed. The absolute difference between the methods for each sample was determined and compared overall and for various subgroups. The number of patient samples achieving National Cholesterol Education Program–defined LDL goal was determined and compared for both methods. A total of 20,224 lipid profiles were generated and 19,343 were included in the analysis. A strong correlation was found between D‐LDL and C‐LDL (r = 0.94). The absolute difference between the two methods demonstrated an underestimation of C‐LDL of 19.5 ± 11.8 mg/dl. The degree of underestimation increased as the triglyceride level increased (p<0.05). Age within the fifth and sixth decades resulted in significantly higher differences compared with age in the eighth decade or greater (p<0.05). Female sex and elevated body mass index also resulted in increased discrepancies between the two methods (p<0.05 for both). Seventy‐six percent of the lipid profiles were derived from patients with coronary heart disease (CHD) or a CHD risk equivalent. Approximately one half of these patients met their LDL goal when LDL level was measured versus calculated (p<0.0001). Conclusion. When compared with D‐LDL, an underestimation of approximately 20 mg/dl was found with C‐LDL, resulting in a loss of LDL goal attainment for half of the patients with CHD or a CHD risk equivalent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1592/phco.24.2.167.33142

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Lindsey, C. C., Graham, M. R., Johnston, T. P., Kiroff, C. G., & Freshley, A.
Venue
Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy
Publisher
Wiley
Published
2004-02
Volume
24
Issue
2
Pages
167-172
ISSN
  • 0277-0008 (ISSN-L)
  • 1875-9114
OpenAlex
W1964976687
Cited by
59
References
4
FWCI
2.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.