Hydroxyapatite and Their Use As Coatings in Dental Implants: A Review

Ong, Joo L., Chan, Daniel C. N.·2000·Critical Reviews™ in Biomedical Engineering

Abstract

At present, no standard manufacturing guideline exists for depositing hydroxyapatite (HA) on implant surfaces. Although animal and in vitro studies have reported on the benefits of using HA-coated implants as well as the risks of dissolution, these short-term studies did not demonstrate that the dissolution of the HA coating leads to a loss of implants. In addition, many in vivo and clinical studies did not include the chemical and structural characterization of the coatings, and thus comparisons between studies are difficult. In the clinics, the recommendation is that HA-coated screw implants be used for the anterior maxilla and posterior mandible where the bone depth exceeds 10 mm and when the cortical layer is thinner and spongiosia is less dense. In the posterior maxilla or when the cortical layer is very thin with low density, the use of HA-coated cylindrical implants is recommended. However, there are concerns for using HA-coated implants. The clinician needs to take into consideration the enhanced bacterial susceptibility of HA coatings compared with titanium implants. In addition, the clinician needs to consider the possible failure of HA coatings as a result of coating-substrate interfacial fracture. Finally, besides the surgical skills, it is also important that the clinical investigators be well versed with the materials characterization needed for HA-coated implants, the problems associated with the current HA coatings, and the indications for use. In addition, the correlation between well characterized coatings and their effect on bone formation rate and long-term implant success, coating-implant interfacial strength, and alternative superior coating process need to be investigated further.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1615/critrevbiomedeng.v28.i56.10

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 56 references

Cited by

See all 315

Metadata

Authors
Ong, J. L., & Chan, D. C. N.
Venue
Critical Reviews™ in Biomedical Engineering
Publisher
Begell House
Published
2000
Volume
28
Issue
5-6
Pages
667-707
ISSN
0278-940X (ISSN-L)
OpenAlex
W1974661733
Cited by
315
References
56
FWCI
7.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hydroxyapatite and Their Use As Coatings in Dental Implants: A Review. https://app.cochat.ai/papers/10.1615/critrevbiomedeng.v28.i56.10
The paper
Ong, J. L., & Chan, D. C. N. (2000). Hydroxyapatite and Their Use As Coatings in Dental Implants: A Review. Critical Reviews™ in Biomedical Engineering. https://doi.org/10.1615/critrevbiomedeng.v28.i56.10

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.