The DOI matches its Crossref record.
Hemodynamic Parameters and Early Intimal Thickening in Branching Blood Vessels
Abstract
Intimal thickening due to atherosclerotic lesions or intimal hyperplasia in medium to large blood vessels is a major contributor to heart disease, the leading cause of death in the Western World. Balloon angioplasty with stenting, bypass surgery, and endarterectomy (with or without patch reconstruction) are some of the techniques currently applied to occluded blood vessels. On the basis of the preponderance of clinical evidence that disturbed flow patterns play a key role in the onset and progression of atherosclerosis and intimal hyperplasia, it is of interest to analyze suitable hemodynamic wall parameters that indicate susceptible sites of intimal thickening and/or favorable conditions for thrombi formation. These parameters, based on the wall shear stress, wall pressure, or particle deposition, are applied to interpret experimental/clinical observations of intimal thickening. Utilizing the parameters as "indicator" functions, internal branching blood vessel geometries are analyzed and possibly altered for different purposes: early detection of possibly highly stenosed vessel segments, prediction of future disease progression, and vessel redesign to potentially improve long-term patency rates. At the present time, the focus is on the identification of susceptible sites in branching blood vessels and their subsequent redesign, employing hemodynamic wall parameters. Specifically, the time-averaged wall shear stress (WSS), its spatial gradient (WSSG), the oscillatory shear index (OSI), and the wall shear stress angle gradient (WSSAG) are compared with experimental data for an aortoceliac junction. Then, the OSI, wall particle density (WPD), and WSSAG are segmentally averaged for different carotid artery bifurcations and compared with clinical data of intimal thickening. The third branching blood vessel under consideration is the graft-to-vein anastomosis of a vascular access graft Suggested redesigns reduce several hemodynamic parameters (i.e., the WSSG, WSSAG, and normal pressure gradient [NPG]), thereby reducing the likelihood of restenosis, especially near the critical toe region.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
Meng, H., Wang, Z., Hoi, Y., Gao, L., Metaxa, E., Swartz, D. D., & Kolega, J. (2007) · Stroke · doi:10.1161/strokeaha.106.481234 · Cited by 606
Peña, E., Calvo, B., Martínez, M. A., & Doblaré, M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.030 · Cited by 506
Endothelial Cell Sensing of Flow Direction
Wang, C., Baker, B. M., Chen, C. S., & Schwartz, M. A. (2013) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.113.301826 · Cited by 294
Peña, E., Calvo, B., Martínez, M. A., Palanca, D., & Doblaré, M. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.01.009 · Cited by 285
Metadata
- Authors
- Archie, Jr., Hyun, S., Longest, P. W., Kleinstreuer, C., Truskey, G. A., & Buchanan, J. R.
- Venue
- Critical Reviews in Biomedical Engineering
- Publisher
- Begell House
- Published
- 2001
- Volume
- 29
- Issue
- 1
- Pages
- 1-64
- ISSN
- 0278-940X (ISSN-L)
- OpenAlex
- W2034989927
- Cited by
- 250
- References
- 0
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hemodynamic Parameters and Early Intimal Thickening in Branching Blood Vessels. https://app.cochat.ai/papers/10.1615/critrevbiomedeng.v29.i1.10
- The paper
- Archie, Jr., Hyun, S., Longest, P. W., Kleinstreuer, C., Truskey, G. A., & Buchanan, J. R. (2001). Hemodynamic Parameters and Early Intimal Thickening in Branching Blood Vessels. Critical Reviews in Biomedical Engineering. https://doi.org/10.1615/critrevbiomedeng.v29.i1.10
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.